2
SAFETY WARNINGS
You will find various types of safety information on the following pages
and on the labels attached to Graymills equipment. The following
Safety Statements explain their meaning:
This is the safety alert symbol. It is used to alert you to potential
personal injury hazards. Obey all safety messages that follow
this symbol to avoid possible injury or death.
DANGER
indicates a hazardous situation
which, if not avoided, will result in death or
serious injury.
WARNING
indicates a hazardous situation
which, if not avoided, could result in death or
serious injury.
CAUTION
, used with the safety alert symbol,
indicates a hazardous situation which, if not
avoided, could result in minor or moderate
injury.
CAUTION
, used without the safety alert symbol,
is used to address practices not related to
personal injury.
The
NOTE
symbol means that failure to follow
these instructions could cause damage to the
equipment or cause it to operate improperly.
Reference Figures are located on Page 5.
Never work with equipment you feel may be unsafe. Contact
your Supervisor immediately if you feel a piece of equipment is
in an unsafe condition.
Never uSe a flammable or CombuStible fluid iN the
tempeSt. uSe oNly NoNflammable, NoN-CombuStible,
water-baSed, low foamiNg CleaNiNg CompouNdS iN
thiS maChiNe.
do Not CoNtamiNate CleaNiNg fluid with aNy
flammable or CombuStible material SuCh aS gaSoliNe,
alCohol, miNeral SpiritS, etC. draiN partS to be
CleaNed of aNy flammable material or CombuStible
material before plaCiNg iNSide CleaNiNg taNk. eveN
Small quaNtitieS CaN Create a daNgerouS fire
hazard.
always wear appropriate safety items such as gloves, apron, safety
glasses or goggles when loading, using or unloading or cleaning the
tempest.
follow all directions, warnings and Cautions that are in the material
Safety data Sheet (mSdS) for the cleaning detergent being used.
in an accident where any cleaning solutions are splashed on clothing
follow mSdS. remove wet clothing promptly and thoroughly wash
body areas that have been in contact with the solution. do Not permit
saturated clothing to remain in contact with skin. industrial cleaners can
cause irritation to some individuals.
Cleaning solutions may irritate skin and eyes. if splashed in eyes, flush
thoroughly with water. Consult material Safety data Sheet (mSdS) and
a physician.
• If you have any questions regarding the correct cleaning fluids
to use in this unit, call graymills at 773-248-6825 and ask for
Customer Service. we recommend our low foaming aquatene
™.
unit must be properly grounded to prevent electric shock hazard.
Connect only to three prong outlet. Should plug or cord become
cracked, frayed, damaged in any way, it should be repaired/replaced
immediately by a qualified electrician.
Never use an extension cord.
Since operator safety is at all times a priority, this unit is equipped
with a ground fault interrupter (gfi). Should plug or cord require
replacement, it should be wired by a licensed electrician to the gfi in
the control box.
all electrical connections should conform to national/local codes and
be made by qualified personnel.
before performing any maintenance on this unit, be sure to disconnect
electric power.
prior to changing cleaning fluid or servicing the tempest, make sure
that all moving parts have stopped and that heating element and
cleaning solution have cooled.
pump operation is controlled by depressing an air switch foot pedal.
for safety, if this must be replaced, use only the same air switch, not an
electrically operated one.
keep pump and motor clean and free of all contaminates. Never allow
any liquids to come into contact with motor or electrical systems as an
electric shock hazard could result.
thermostat and pressure parameters have been factory set and must
never be tampered with.
•
The Tempest 10, 10S and 20S Units are preset to operate up to
600 PSI.
operating with pressure greater than 600 pSi can create a
hazardouS situation.
• Tempest is equipped with a pressure relief valve in the spray cabinet
(figure 6). when pressure is relieved, the valve automatically resets.
Should pressure inside spray delivery system reach an unsafe level,
relief valve will vent excess pressure back into cabinet. this valve
must be kept clean and free of all contaminants to insure its proper
functioning. activation of the pressure relief valve is not expected
during normal operation.
do Not start spray pump unless you have a firm grip on the nozzle. if
nozzle is dropped, stop pump immediately. an unrestrained hose and
nozzle could cause injury, damage to cabinet and parts in it, as well as
break the window, causing possible injury. restrain parts which might
be violently moved by high pressure spray.
Never aim spray directly at gloves or anything other than parts to be
cleaned.
Tempest is equipped with a safety interlock switch that prevents the
pump from operating unless the cabinet door is closed and secured
with door hasps.
Never override safety interlock switch or operate this
unit if the safety interlock switch is not functional.
Never open cabinet door when spray pump is operating, or try to
override the safety switch. if switch fails, do Not use tempest until
replaced.
do Not overload unit. maximum capacity is 500 pounds.
be careful to avoid hot areas within the cleaning chamber when
opening unit.
parts will be heated during cleaning. wear appropriate clothing and
protection.
Never operate unit with a cleaning solution reservoir level below
minimum or activate heater when it is not immersed in liquid.
do Not operate unit without a filter bag.