795-94053 - 5
SAFETY PRECAUTIONS (Continued)
WARNING: Hearing protection is required for the user of this equipment.
This equipment is intended to be utilized indoors in an ambient temperature of 50°F
to 95°F.
The benchtop systems are all protected by splashing water and debris to a rating of
IP 23.
This system contains one power cord that is required to be attached to a properly
rated three wire fusible disconnect with a grounding connection capable of handling
twice the rated current. The wires are colored as follows: black - hot / ungrounded,
white - return / grounded, green & yellow - protective earth. The system also contains
one drain valve for tank content drainage. The drain can be plumbed into a facility
drain or remaining unplumbed for added mobility on draining locations.
Recommend the use of NRTL approved electrical plug for use with this system.
Select the appropriate plug for the voltage and current rating of the unit as per the
respective national standard. When the plug is installed, make sure the wires are cut
so that the protective earth is the last to take the strain. Electrical plugs should be
installed only by a certified electrician.