background image

15

16

NiCd/ NiMH battery charge setup 

LiPo, Lilon, LiFe, NiCd, NiMH, Pb battery charge process 

Charge mode per battery type

Pb battery charge setup

- Cut-Temp

- Max Capacity 

- Safety Timer

- Store Volt

- Current

- Peak Sens

- Tricke

- Cut-Temp

- Max Capacity 

- Safety Timer

- Voltage
- Current
 

- Cut-Temp

- Max Capacity

- Safety Timer

:  Cut-off  temperature.  Detected  using  an  optional  temperature  sensor,  a  safety  cut-off 
temperature can be set to automatically terminate charging or discharging processes. This 
termination can occur for battery temperatures exceeding a preset value.
: The maximum capacity setting is used to terminate a charge. The maximum capacity is 
used to prevent the battery capacity from exceeding a preset percentage. Damaged, poorly 
balanced, or improperly programmed batteries can be overcharged without this limitation.
: The safety timer can be used to terminate a charge for charging times that exceed 
this preset time period. This timer can be used to protect the battery from damage.
: The battery voltage in the store mode. This parameter is used to terminate a charge 
for voltages that reach a preset voltage value.

: Charge current. - Tapping the INC/DEC buttons can activate and edit this parame-
ter. The default charge current is set to 1C (1 x capacity). This value can be adjusted 
from 0.1 to 20 Amps, operating within the 400W limitation.
: Delta-peak cut-off voltage. - This parameter is used to charge the NiCd/ NiMH 
batteries. As the pack voltage peaks, the pack becomes hot and the pack voltage 
drops off. This charger terminates the charging process using a Delta-peak cut-off. 
The default parameter is 3mV/cell for the NiMH batteries and 7mV/cell for the NiCd 
batteries.
: Trickle charge current. - With NiCd and NiMH type batteries, a trickle charge pro-
cess is recommended after the main charge has completed, allowing the battery to 
become fully charged and ready to be used. The recommended trickle charge current 
is approximately 10% of the pack capacity (possible to set to a max of 500mA).
: Cut-off temperature. - Used with an optional temperature sensor, a safety cut-off 
temperature value can be specified, allowing the charging or discharging processes to 
automatically terminate for battery temperatures exceeding a preset value.
 The maximum capacity setting is used to terminate charging processes for battery 
capacities exceeding the selected percentage values. Damaged or improperly pro-
grammed batteries can be overcharged without a proper setting of this parameter.
: The safety timer can be used to terminate the charging process for charging times 
that exceed a preset time period. This timer is used to protect the batteries.

: Maximum cell voltage. - CV (Constant Voltage)
: Charge current. - Tapping the INC/DEC buttons can activate and edit the param-
eters. The   default charge current is set to 1C (1 x capacity). This value can be 
adjusted from 0.1 to 20 Amps, operating within the 400W limitation.
:  Cut-off temperature. -  Used with an optional temperature sensor, a safety cut-off 
temperature can be set, allowing the charging or discharging processes to automatically 
terminate at battery temperatures exceeding the preset temperature value.
: The maximum capacity setting is used to terminate charging processes that result in 
battery capacities exceeding a preset percentage value. Damaged, poorly balanced, 
or improperly programmed batteries can be overcharged without this limitation.
: The safety timer can be used to terminate the charging process for charging times 
that exceed a preset time period. This timer is used to protect the batteries.

The programmed data are stored in the memory and used to charge the batteries. Tapping the Enter 
button initiates the charging process. The balance connector verification, the charge mode verification, 
the number of cells to be charged, and the delay time setup should be finished prior to the charging 
process. For an improperly programmed setup, the charger will initiate a 5-second countdown without 
any external controls.

Below picture shows the sequence of charging

[ AUTOMATIC ]
NiCd/NiMH : This step is an automatic charging process, first determining the number of cells and then mon-
itoing the charge current. The charger calculates the internal resistance and charge current for every period 
of time, automatically adjusting the charge current to ensure the delivery of the optimal charge current to your 
pack.  The PEAK SENS values (NiCd=7mV/cell, NiMH=4mV/cell) are applied automatically. The CUT-TEMP values 
can be programmed.

The charger verifies the connection with 

the balance board. This step is an auto-

matic process.

Both the charge mode and the delay time are programmed 
parameters. 
To activate, tap the box to become blue. Tap the DEC/INC 
button to select the desired mode.
Charge modes are explained below

After a 5-second countdown, the charger initiates the 
charging process. Tapping the Enter button            initi-
ates the charging process immediately.

The Start Delay Time can be set at values ranging from 
1-150 minutes.
The charger initiates the battery charging process after 
the preset time has expired.

Charge mode selection

Delay time setup

Содержание Polaron EX

Страница 1: ...OPERATING INSTRUCTION Pease read this manual thoroughly Keep this manual in a convenient place for quick and easy reference No S2011 2 Channels DC Charger ...

Страница 2: ...USA OPENHOBBY LLC The HoTT trademark is used with permission of SJ Inc 4386066 Internet sales site Firmware Upgrade Please visit us at www openhobbby com to stay up to date with the latest software and firmware for your products Customer support We are happy to assist you with any question by e mail or phone Customer service hours are from 9 am to 5 pm PST Pacific Standard Time during the workweek...

Страница 3: ...Do not attempt to charge dead or damaged batteries Use identical batteries in the charger Do not attempt to charge a battery pack containing different types of batteries Do not use a too short or damaged cables Ensure that each channel has a completely charged pack Do not use near a flammable object Use only in well ventilated areas Explosive gases may be generated during the operation of this pro...

Страница 4: ...annel contains 20 memories 20ea x 2CH 40 memories Yes 88 2 x 203 4 x 196 3 mm 3 47 x 8 00 x 7 73 inches 1368 g 48 25 oz Connect the battery pack to a balance board Without this connection either the batteries or the charger may be damaged Do not charge a battery with a voltage below 2 8V per cell If this type of battery is forced to charge the pack can be damaged and in extreme cases can result in...

Страница 5: ...arge discharge status LED bar Temperature sensor port Motor sensor DC Input LED Indicator for charge discharge Battery socket USB 5V 2 5A Servo test Dynamic Cooling Fan W Speed control Channel selection button Balance port Ext Module Speed Controller Setting TOP FRONT BACK RIGHT ...

Страница 6: ...on the spe cific charger channel with the positive lead connected to the red socket and the negative lead connected to the black socket Only connect the battery to the charge lead AFTER the charge lead has been connected to the charger as the connectors on the charge lead could touch together and cause the battery to short circuit capacity than other cells over time the pack can become unbalanced ...

Страница 7: ...ck to the previous page IMPORTANT The battery parameters must be entered correctly as incorrect values may cause the charger to damage your battery which can result in a fire Battery names can be written with 12 characters Tapping the Clr button shown in the red circles above erases the default name allowing the new name to be entered To enter the battery names ABC abc or 123 each page with the up...

Страница 8: ...ting of this parameter The safety timer can be used to terminate the charging process for charging times that exceed a preset time period This timer is used to protect the batteries Maximum cell voltage CV Constant Voltage Charge current Tapping the INC DEC buttons can activate and edit the param eters The default charge current is set to 1C 1 x capacity This value can be adjusted from 0 1 to 20 A...

Страница 9: ...ging under constant current conditions the charger will charge discharge to store the pack with a constant voltage CC CV is applied to N STORE FAST is applied to Q STORE Charge modes for the POLARON EX CHARGER CC CV Normal charge FAST Fast charge N STORE Normal store charge Q STORE Quick store charge CV LINK The packs that have the same number of cells and capacity can be charged simultaneously If...

Страница 10: ...ctively DISCHARGE PAGE Tapping the DISCHARGE icon on the main page will access the discharge mode The pro gramming setup and the page transition are the same as described for the CHARGE mode On the main page tap the DISCHARGE icon to start the discharge process This page shows discharge setup for selecting LiPo Lilon LiFe NiCd NiMH Pb batteries Tapping the part in the red circle image on the left ...

Страница 11: ...ll NiMH 0 8V cell LiIon Po 3 0V cell LiFe 2 5V cell Pb 1 8V cell are applied Charging the Lithium and Pb batteries after discharging does not affect the battery performances The preset CUT TEMP is used in this discharge mode NORMAL The charger will stop the discharging process every minute to calculate the average resistance LINEAR The charger will discharge the pack stopping once after 3 minutes ...

Страница 12: ...ss respectively Tapping the CYCLE icon on the main page will access the cycle mode Tapping the data box will activate this parameter blue Tapping the DEC INC buttons will access the pro gram for the parameters LiPo Lilon LiFe NiCd NiMH Pb battery cycle pages Tap the CYCLE icon on the main page to access the cycle mode Tapping the part in the red circle will activate blue this parame ter allowing t...

Страница 13: ...g er to immediately initiate the charging process This page left shows the battery check process after a con nection to the balancer has been established The next page is accessed automatically Tapping the Enter button will cause the charger to immediately initiate the charging process Tap the part in the red circle left to display the set current window The charge discharge current parameters use...

Страница 14: ...e to access the data view mode There are 3 view modes After activating the buttons the data can be programmed by tapping the DEC INC buttons In the Cycle data and Graph data modes the data can be accessed In the Normal data mode the parameters can not be programmed BALANCE MODE 3 1 BALANCE MODE 1 This page above left shows the basic date of the battery 2 BALANCE MODE 2 This page above center shows...

Страница 15: ...f sounds are available Sound Time The times available for the charger are ON OFF 5sec 15sec and 1min Beep This parameter can be turned on off to select either an internal or an external button LCD Bright Backlight brightness can be adjusted 1 20 steps Temp Scale The temperature unit can be changed Sound Vol The sound level can be adjusted 1 5 steps Date Time Date month year time setup Alarm 1 The ...

Страница 16: ...Min Mid Max signal Auto loop time Output signal The 3 sensors at the top indicate if the motor is OK or not RPM and Kv are shown at the bottom Tap the relevant buttons The servo is operated in accordance with the preset signal The parameters of each article can be changed by tapping the DEC INC buttons After entering the Auto loop time 0 1 5 0sec tap the Enter button High power servos may not func...

Страница 17: ...ct the motor to a 4mm banana charge socket Tap the MOTOR icon to access the motor setup mode This page has 3 menus 1 Break In The motor is operated and limited by the preset voltage for the preset time 2 Program Programming requires 4 inputs the voltage the operating time the delay time and the number of cycles After entering each data value tap the Enter button The charg er will repeat to load th...

Страница 18: ...rmer bag to the charger output terminal and the temperature sensor connector Then program the required parameters 2 Tire Warmer This feature can be used to warm rubber tires providing an important competitive edge on the track Connect the tire cup to the charger output terminal and to the temperature connector Then program the required parameters Temperature setup Alarm setup Alarm rings at the pr...

Страница 19: ...while other functions are in operation Both the Car ESC and the Air ESC with a telemetry function can be programmed without an extra programmer Select the ESC setup icon Turn on the model s power Then connect the telemetry terminal to the EXT MODULE allowing the data to be displayed and programmed pages 38 39 The data can be programmed with 6 buttons 1 The 3 modes can be accessed by the DEC INC bu...

Страница 20: ...be rebooted for the charging mode Tap anywhere on the screen to complete the Touch calibra tion Then return to the Start up page FACTORY SETUP AND SCREEN CALIBRATION Button for Channel changing and initializing Press and hold the button Turn on the charger s power 1 Return to the factory setup 2 Touch screen calibration 3 Image and sound update 4 Checking the balance port The user can adjust No 1 ...

Страница 21: ...battery connected to the charger A Reverse Polarity error message indicates that the battery is plugged in backwards inverting the positive to negative connections An Open Circuit error message indicates that the charging discharging battery has been disconnected during an operation A Short Circuited error message may indicate multiple errors including faults at the charger output leads at the bat...

Страница 22: ...ceeds the value in the MISC MOTOR function A Balancer Port error message indicates that the balance connector has been disconnected A Low Output Volt error message indicates that either the voltage setup is below the requirements for the charging discharging battery or the number of cells has been improperly selected A Sync Command error message indicates that the preset number of cells and the nu...

Страница 23: ... the first time the process may terminate within minutes This stoppage does not indicate a problem This stoppage results from an unstabilized battery To stabilize the batteries charge the batteries either after increasing the delta peak value or after performing a discharging process followed by a cooling down period Do not use the batteries if the charged capacity of the battery exceeds the speci...

Страница 24: ... pack as a significant drop in voltage under load will occur that can dramatically reduce the number of charge discharge cycles that the battery pack will hold Disposal of the Lithium battery packs requires that the pack be completely discharged Use a light bulb electric motor or similar to completely discharge the pack Do not allow a Lithium battery pack to short circuit A short circult may resul...