mode manually, and the model should respond normally to control commands. If this does not occur

 

with 100% reliability, the system should not be used. Contact your local Service Department of 

 

Graupner GmbH & Co. KG.

•  Range-check mode is usually terminated manually when the user presses the BIND / RANGE but
 

ton, but it terminates automatically after about ninety seconds in any case. The red LED now glows

 

constantly again, while the green LED either glows constantly or 

fl

 ashes continuously, according to

 

the Country setting.

•  We recommend that you check effective radio range before every 

fl

 ight. While you are carrying 

 

out the check, simulate all the servo movements which will take place when the model is in 

fl

 ight. 

 

The ground range must always be at least 

fi

 fty metres in order to ensure safe, reliable model con-

 trol. 

Note:

Range-check mode is usually terminated manually when the user presses the BIND / RANGE button, 
but it terminates automatically after about ninety seconds in any case.

CAUTION:

During normal operations (i. e. when controlling a model) never press and hold the programming 
button on the transmitter module!

6.3. Fail-Safe function (RX Failsafe)

In its default state (as delivered) the receiver is set to “Hold” mode, i.e. if a fail-safe situation occurs, all 
the servos connected to it maintain the last position detected as valid. In this mode the red LED on the 
receiver lights up when interference occurs, and the red LED on the transmitter goes out. The transmit-
ter also starts beeping about once per second as an audible warning.
You can exploit the safety potential of the fail-safe option by at least programming the throttle channel to 
respond to a fail-safe situation: the throttle channel of an engine-powered model should be set to idle, 
the throttle channel of an electric-powered model to “stop”, and the throttle channel of a model helicop-
ter to “Hold”. You can program the fail-safe function either in the Telemetry menu under “RX Failsafe” 
(5.2.3), or on the transmitter module: repeated brief presses of the BIND / RANGE button on the trans-
mitter module cycle through the fail-safe modes (fail-safe on / off, hold-mode, or standard). 

Locate the 

BIND / RANGE button on the back of the module, and hold it pressed in while you switch the transmitter 
on. Release the button again once it is switched on.

• Fail-Safe 

mode: 

when you press the BIND / RANGE button, the transmitter beeps once; the red

 

and green LEDs glow constantly.

 

It is now possible to program positions to which the servos will move in a Fail-Safe situation; this

 

occurs after a “Hold” period of 0.75 seconds: move the corresponding transmitter controls (sticks,

 

rotary knobs, INC / DEC buttons etc.) to the desired Fail-Safe positions SIMULTANEOUSLY, then 

 

hold the BIND / RANGE button pressed in for three to four seconds. When you release the button,

 

both the red and green LEDs should light up constantly, and the transmitter should not emit an au-

 

dible signal: the transmitter now reverts to Control mode. If this does not occur, repeat the procedu-

 re.

•  Hold mode (recommended for model helicopters): 

when you press the BIND / RANGE button,

 

the transmitter beeps twice; the red LED lights up constantly, and the green LED goes out (factory

 default 

setting).

 

If interference occurs, all servos programmed to “Hold” remain at the last position detected by the 

 

receiver as correct; this situation is maintained until such time as the receiver picks up a new, valid 

 control 

signal.

 

You can save your selection by holding the BIND / RANGE button pressed in for three to four se-

 

conds. When you release the button, both the red and green LEDs should light up constantly, and 

 

the transmitter should not emit an audible signal: the transmitter now reverts to Control mode. If this

 

does not occur, repeat the procedure.

• Fail-Safe 

OFF: 

when you press the BIND / RANGE button, the transmitter beeps three times; the

 

green LED glows constantly, the red LED goes out.

 

You can save your selection by holding the BIND / RANGE button pressed in for three to four se-

 

conds. When you release the button, both the red and green LEDs should light up constantly, and 

 

the transmitter should not emit an audible signal: the transmitter now reverts to Control mode. If this

 

does not occur, repeat the procedure.

Содержание HOTT M-G2

Страница 1: ...ata View RX DATAVIEW 07 5 2 2 Servo Data RX SERVO 08 5 2 3 Failsafe Setup RX FAILSAFE 09 5 2 4 Mixer Setup RX FREE MIXER WING MIXER 11 5 2 5 Expo functions RX CURVE 12 5 2 6 Servo test RX SERVOTEST 13...

Страница 2: ...PREPARING THE SYSTEM mc series First remove your previous RF module For details of this procedure please refer to the appropriate chapter in the operating instructions supplied with your radio control...

Страница 3: ...he connector contacts are correctly positioned otherwise they could be damaged when you plug the module in do not use force The aerial connector can now be in serted in the socket on the module using...

Страница 4: ...MC SERIES 1 1 2 2 1 1 03 Manual Module M G2 33302 Fig 5 Fig 6 Fig 6 Fig 7 Fig 7 Fig 8 Fig 8 Fig 9 Fig 9 Fig 10 Fig 10 Fig 11 Fig 11 Fig 12 Fig 12 Use the white washer securing the telescopic antenna 1...

Страница 5: ...cover engage the two lugs in the left hand side of the module case then fit the two screws to secure it Check that it is correctly located Fig 13 5 We recommend that you cut openings for the BIND RAN...

Страница 6: ...must be used for programming if you are using any of the following transmitters mx 22 Order No 4801 4802 mc 19 Order No 4821 mc 22 Order No 4818 and mc 18 Order No 4835 The following instructions desc...

Страница 7: ...autic module is used set MULTIC to 00 Note The cycle time PERIOD must be set to 20 msec the channel sequence CH OUTPUT TYPE to SAME so that the function is activated Parameters which have different op...

Страница 8: ...check the receiver installation and the power supply systems in your model and radio control system When operating your model this value should not fall below 90 dBm If it does you should reduce the d...

Страница 9: ...m operating voltage L R VOLT displays the lowest receiver operating voltage since the last time the receiver was switched on If this voltage differs significantly from the actual operating voltage R V...

Страница 10: ...vailable separately for each direction Cycle time PERIOD at this point it is possible to define the speed of the servos response to move ments of the transmitter controls This adjustment applies to al...

Страница 11: ...This can be exploited for example to prevent the operation of a retractable undercarriage or similar function if the receiver is switched on accidentally However during normal model operations the cor...

Страница 12: ...R appears on the screen Display Description Setup MODE Mode 1 2 3 MASTER CH Master channel 0 1 8 SLAVE CH Slave channel 0 1 8 SLAVE TRAVEL Limit Servo travel negative 0 150 SLAVE TRAVEL Limit Servo tr...

Страница 13: ...the neutral position but its response reverts to a more linear curve with increasing control surface travel B linear setting the servo s response to stick movements is linear C EXPO setting i e the se...

Страница 14: ...ashes at top right in all the Smartbox s receiver displays at the same time the parameter R VOLT is displayed in inverse form in the receiver data display RX DATAVIEW Receiver temperature monitor ALAR...

Страница 15: ...iver must be programmed as SUMI Note that the signal only ever moves towards SUMI The receiver outputs are addressed in sequence at a frame rate of 20 ms 30 ms with the GR 24 re ceiver Order No 33512...

Страница 16: ...must be connected to this unit as only the Master receiver transmits sensor data using the downlink channel The second and all further receivers operate in parallel with the Master receiver but in Sl...

Страница 17: ...repeated brief presses of the BIND RANGE button on the trans mitter module cycle through the fail safe modes fail safe on off hold mode or standard Locate the BIND RANGE button on the back of the modu...

Страница 18: ...reen LED flashes continuously Once you have selected the Country setting save it in the transmitter by holding the BIND RANGE button pressed in for about three seconds When you release the button the...

Страница 19: ...er before the beep display OFF appears no log data is saved By default always the transmitter and receiver data with integrated telemetry or transmitter only wit hout integrated telemetry are recorded...

Страница 20: ...to the module M G2 7 1 Update procedure Ensure that the adapter lead is configured as shown in the illustrations and is connected correctly to the transmitter or receiver Start the Graupner Firmware U...

Страница 21: ...on the receiver also light up when the process is complete the green LED goes out and the red LED starts flashing Switch your transmitter receiver off and disconnect the ad apter lead Caution after c...

Страница 22: ...isierte Normen Harmonised standards applied EN 60950 2006 EN 301 489 1 V1 7 1 EN 301 489 3 V1 4 1 EN 300 328 V1 7 1 Health and safety requirements pursuant to 3 1 1 Article 3 1 a Protection requiremen...

Страница 23: ...e recycled and re used You can make an important contribution to the protection of our common environment by re using the product recycling the basic materials or recycling redundant equipment in othe...

Страница 24: ...soci t Graupner GmbH Co KG Henriettenstra e 94 96 73230 Kirchheim Teck Allemagne accorde sur ce produit une garantie de 24 mois partir de la date d achat La garantie prend effet uniquement sur les vic...

Страница 25: ...____________________________________________________ ____________________________________________________________ ____________________________________________________________ _________________________...

Страница 26: ...________________________ ____________________________________________________________ ____________________________________________________________ _____________________________________________________...

Страница 27: ...________________________ ____________________________________________________________ ____________________________________________________________ _____________________________________________________...

Страница 28: ...t supplier We accept no liability for printing errors Sous r serve de modifications et de possibilit de livraison Livraison uniquement au travers de maga sins sp cialis s en mod lisme Nous pourrons vo...

Отзывы: