12 / 20
S1012_GR-12L_DE_V1sh
Se
tting and displ
ay of the receiver se
ttings
The receiver-side menus can be viewed and some
times
changed
using a suitable HoTT transmi
tt
er or the SMART-BOX. You can
find
out how to open the menus of a receiver in the "Telemetry"
section
of the corresponding manual as well as a detailed descrip
tion
of the
receiver menus on the r
especti
ve product page at
www.graupner.
com
on the Internet.
Note
The values shown in the following display illustra
tions
always show
the standard values.
Display "RECEIVER"
ALARM
VO
L
T
•
If "SERVO" or "SENSOR" is visible in the "CH5 FUNCTION" line
described below, the opera
ting
voltage of the receiver is moni-
tored via the limit value set in the v
alue field of "ALARM
VOLT".
•
If "BATT-V" is visible in the "CH5 FUNCTION" line described below,
the opera
ting
voltage of the drive ba
tt
ery connected via "BATT-V"
is monitored via the limit value set in the value
field
of "ALARM
VOLT".
In both cases, the actual voltage is shown in the transmi
tter's
display
in the "Receiver voltag
e" field.
If the voltage drops under the set limit value, a transmi
tt
er-side
alarm takes place in the form of an acous
tic
signal (interval beep long
/ short).
Adjustment range: 2,5 … 22,5 Volt in 0,1 Volt steps.
ALARM TEMP
This op
tion
monitors the receiver temperature. If the set limit is
exceeded, a transmi
tt
er-side alarm takes place in the form of a con-
tinuous beep.
Adjustment range: 30 … 80 °C
PERIOD
In this line, specify the periods for the individual channel pulses. This
se
tting is t
ransferred for all control channels.
If your system is used exclusively with digital servos, you can set a
cycle
time
(frame rate) of 10 ms. If your system includes some or
uses exclusively analogue servos, always select 20 ms since the ana-
logue servos may be overloaded and respond by "ji
tt
ering" or "growl-
ing".
Adjustment range: 10 or 20 ms
TELEMETRY
SETTING & DATA VIEW
SENSOR
DISPLAY RF STATUS
SELECT ANNOUNCE
RX DATA ON
ALARM SETTING
RECEIVER 2.05
ALARM TEMP: 65°C
ALARM VOLT: 3.7V
CH5 FUNCTION:SERVO
PERIOD: 20ms
RSSI CH : OFF
CH6 FUNCTION:SERVO
F.RESET : No