GRAUPNER HoTT GR-12L S1012 Скачать руководство пользователя страница 12

12 / 20

S1012_GR-12L_DE_V1sh

Se

tting and displ

ay of the receiver se

ttings

The  receiver-side  menus  can  be  viewed  and  some

times

  changed 

using a suitable HoTT transmi

tt

er or the SMART-BOX. You can 

find 

out how to open the menus of a receiver in the "Telemetry" 

section 

of the corresponding manual as well as a detailed descrip

tion

 of the 

receiver menus on the r

especti

ve product page at 

www.graupner.

com

 on the Internet.

Note

The values shown in the following display illustra

tions

 always show 

the standard values.

Display "RECEIVER"

ALARM 

VO

L

T

  If "SERVO" or "SENSOR" is visible in the "CH5 FUNCTION" line 

described below, the opera

ting

 voltage of the receiver is moni-

tored via the limit value set in the v

alue field of "ALARM 

VOLT". 

  If "BATT-V" is visible in the "CH5 FUNCTION" line described below, 

the opera

ting

 voltage of the drive ba

tt

ery connected via "BATT-V" 

is monitored via the limit value set in the value 

field

 of "ALARM 

VOLT". 

In both cases, the actual voltage is shown in the transmi

tter's

 display 

in the "Receiver voltag

e" field. 

If  the  voltage  drops  under  the  set  limit  value,  a  transmi

tt

er-side 

alarm takes place in the form of an acous

tic

 signal (interval beep long 

/ short).
Adjustment range: 2,5 … 22,5 Volt in 0,1 Volt steps.

ALARM TEMP

This  op

tion

  monitors  the  receiver  temperature.  If  the  set  limit  is 

exceeded, a transmi

tt

er-side alarm takes place in the form of a con-

tinuous beep.

Adjustment range: 30 … 80 °C

PERIOD

In this line, specify the periods for the individual channel pulses. This 

se

tting is t

ransferred for all control channels.

If your system is used exclusively with digital servos, you can set a 

cycle 

time

 (frame rate) of 10 ms. If your system includes some or 

uses exclusively analogue servos, always select 20 ms since the ana-

logue servos may be overloaded and respond by "ji

tt

ering" or "growl-

ing".
Adjustment range: 10 or 20 ms

TELEMETRY

SETTING & DATA VIEW
SENSOR
DISPLAY RF STATUS
SELECT ANNOUNCE
RX DATA       ON
ALARM SETTING

 RECEIVER   2.05

ALARM TEMP:     65°C

ALARM VOLT:     3.7V

CH5 FUNCTION:SERVO

PERIOD:         20ms

RSSI CH :    OFF

CH6 FUNCTION:SERVO

F.RESET :     No

Содержание HoTT GR-12L S1012

Страница 1: ...EN No S1012 6 channel 2 4 GHz HoTT receiver GR 12L HoTT Manual C o p y r i g h t G r a u p n e r S J G m b H C o p y r i g h t G r a u p n e r...

Страница 2: ...2 20 S1012_GR 12L_DE_V1sh...

Страница 3: ...ndling the transmitter and the receiver 8 For your safety by handling the batteries 8 Installation 9 Connections 9 Power supply 10 Binding 10 Receiver reset 11 Setting and display of the receiver sett...

Страница 4: ...HoTT system and rst of all to safely control your models If you experience any trouble during operation take the instructions to help or ask your dealer or Graupner Service Centre Due to technical cha...

Страница 5: ...urself about the laws and regulations applicable at your respective starting point before starting the remote control operation Such conditions may di er from state to state but this must be followed...

Страница 6: ...m Operating voltage 2 5 3 6 8 4 V Frequency range 2400 2483 5 MHz Modulation 2 4 GHz FHSS Number of controls 6 Current consumption approx 70 mAh Temperature range 15 70 C Dimensions approx 36 x 21 x 1...

Страница 7: ...a responsible person Operation and use of radio controlled models needs to be learnt If you have never driven such a model then start extra carefully and make sure to be familiar with the reactions of...

Страница 8: ...uction and or modi cation of the product is prohibited Note During transport protect the model and the transmitter from dam ages For your safety by handling the batteries CAUTION Protect the batteries...

Страница 9: ...e cables cannot shift to lie directly adjacent to antennas during ight In the case of carbon bre fuselage at least the last 35 mm of the antennas shall be routed from the fuselage Connections Connect...

Страница 10: ...ously marketed servos speed controllers gyros etc as well as many which are o ered today have a permissible operating voltage range of 4 8 to 6 V Binding To establish a connection with the transmitter...

Страница 11: ...process at any time If a reset has already been performed on an already bound receiver and the associated model memory is active in the switched on trans mitter then the red LED of the receiver GR 12...

Страница 12: ...In both cases the actual voltage is shown in the transmitter s display in the Receiver voltage eld If the voltage drops under the set limit value a transmitter side alarm takes place in the form of an...

Страница 13: ...directly to a connection port of the receiver The receiver and all connected devices would be immediately destroyed CH6 FUNCTION SERVO The connection 5 is suitable for the operation of RC components S...

Страница 14: ...relatetothemixersselected in the MIXER line MASTER CH In this line the MASTER CH signal source or source channel has to be selected Selection range CH 1 CH 6 If no mixer has to be set select 0 SLAVE C...

Страница 15: ...Normal CH4 Normal In this display the direction of rotation of each of the servos con nected to the receiver outputs 1 6 can be set individually select the desired line press or tap on the ENTER key...

Страница 16: ...small chamfers on the sides Do not use force the plug should click into place easily Connect the other end of the adapter lead to the socket of the receiverGR 12LHoTTlabelledwith 5T Thepolarityofthepl...

Страница 17: ...17 20 S1012_GR 12L_DE_V1sh...

Страница 18: ...trieb Deutschland sterreich Niederlande Manufaturer Manufakturer GRAUPNER Co Ltd Post Code 14557 202 809 18 Bucheon ro 198beon gil Bucheon si Gyeonggi do South Korea ZAC Centre 15 Rue Martin Luther Ki...

Страница 19: ...ent lightly rub Warranty conditions grants from the date of purchase of this product for a period of 24 months The warranty applies only to the material or operational defects already existing when yo...

Страница 20: ......

Отзывы: