Domestic hot water systems
1)
–
“
fully pumped system
”
or
“
gravity-fed system
Fully pumped
Domestic Hot Water
system
(PUMPED)
The term for any boiler that uses a pump to
move all the heat from the boiler to every
part of the system is “fully pumped”. As a
rule one pump is used to circulate the water
through valves which divert the flow to the
relevant part of the system (Central heating or
Domestic Hot water). In this type of systems,
both channels of the programmer can work
independently.
Gravity-fed
Domestic Hot Water
system
(GRAVITY)
In gravity fed hot water systems, whenever
the boiler comes on to service heating, there
will inevitably be some circulation through
the hot water storage tank, which will then
heat up. Then there is no possibility to have
independent programs for heating and hot
water.
You can set the desired system in the
INSTALLERS MENU
.
To access to installers menu, the device must be working in
RUN
mode.
10 sec.
INST MENU
DIGI CLOCK
BACKLIGHT
S W CHANGE
PROG TYPE
NR PERIODS
DEFAULT PROG
PUMP GRAVITY
RESET
1. Make sure device is working in
RUN
mode.
2.
Press and hold
buttons at the same time for 10 seconds.
Z
Z
INST MENU
opens and
OK
is flashing.
3.
Confirm with
.
Z
Z
Installers menu is activated.
4. Press 6 x
until
PUMP GRAVITY
is displayed.
5.
Press
to edit settings.
Z
Z
Preset value is flashing.
6.
Press
or to scroll through the menu. Choose your desired
setting (
PUMPED OR GRAVITY) and confirm with
.
Z
Z
The choosen setting is saved.
Z
Z
The next menu item
RESET
is displayed.
7.
Press the
MANUAL SELECTOR
Override
HEATING
HOT WATER
Extra Hour
Mode
DAY/
CH
RUN
TIME
OFF
am
Thu
AUTO
ONCE
CONT
EXT HOUR
+1
+2
+3
07 / 02 / 2013
ON1
OFF
AUTO
ONCE
CONT
EXT HOUR
+1
+2
+3
ON1
DHW
Override
Extra Hour
Mode
OK
Holidays
Select
until programming menu
RUN
is selected.
Z
Z
Function indicator lamp
RUN
is ON.