Chapter 3 Working with RAID Storage Using GVG Disk Utility
74
If the drives you want to designate as hot spares are bound as part of a data LUN, you
must unbind the drives first, then bind them as hot spares. (Refer to “Unbinding LUNs
for reconfiguration” on page 91.) You can configure any disk in the array as a hot spare
drive, however, hot spare drives are available only to RAID Controller to which they are
connected.