AC power requirements
If one of the two power supplies fails, the remaining supply and cord must support the
full load. Your rackmount cabinet must include ac power distribution that can handle
these values.
Size and weight
Copper cable lengths
It is recommended that you use the copper Fibre Channel cables shipped with your
PFR500 when making connections.
Any copper cables you use must meet the appropriate standards for 1-Gbit FC-AL loops.
Such cables are fully shielded, twin-axial, full-duplex cables with DB-9 connectors.
Cables greater than 10 meters must be equalized; cables equal to or less than 10 meters
do not need to be equalized. Do not use copper cables longer than 15 meters for any Fibre
Channel connection in a Profile system.
Power Input
100-120 VAC, 50/60Hz, 6amps
200-240 VAC, 50/60Hz, 3 amps
Item
Measurement
Height
13.34 cm (5.25 in) (3 rack units)
Width
44.83 cm (17.65 in)
Depth
55.88 cm (22 in)
Weight
34.0 kg (75.0 lbs)