2-85
Control Panel Reference
Serial Interface RS232, RS422 Bus Pin Outs
You may use either the RS232 or the RS422 connector depending
upon the standard you have selected. The RS232 connector is the
25-pin, D connector. Pinout is:
Pin # Circuit
C.C.I.T.T.
Signal
2
BA
103
Transmitted Data
3
BB
104
Received Data
4
CA
105
Request To Send (not used)
5
CB
106
Clear To Send
7
AB
102
Signal Gnd, Common Return
8
CF
109
Received Line Signal Detector
The RS422 connector is the 9-pin, D connector. Pinout is:
Pin #
Circui
t
1
Chassis Ground
2
Tx–
3
Rx+
4
Common
6
Chassis Ground
7
Tx+
8
Rx–
9
Common
Remember that the RS422 standard requires the correct
terminating resistor in the Performer which is at the end of the
bus. See page 2 - 32 for instructions.
DC Power Cabling
The control panels and the serial interface are powered by external
transformers. The transformer is either 90-130VAC or 180-260VAC
as stated in your equipment order. Check the label before
plugging the transformer in. (Note that, due to the wide variation
in styles, you must supply the 240VAC plug end.)
Содержание PERFORMER
Страница 1: ...PERFORMER D IG ITAL 10X1 ROUTING SWITCHER Instruction Manual TP3461 01 FIRST PRINTING SEPTEMBER 1994 ...
Страница 8: ...viii Contents ...
Страница 16: ...xiv Safeguards and Notices ...
Страница 32: ...1 12 Section 1 Product Description ...
Страница 118: ...2 86 Section 2 Installation ...
Страница 178: ...3 60 Section 3 Operation Service ...