8
KAM-DEC-4ADC-MUX Instruction Manual
System Requirements
System Requirements
KAM-DEC-4ADC-MUX operation requires 2000NET Network Interface
Module hardware revision 01A1 or greater with software version 4.0.0 or
greater. Systems installed in the 2000T3N frame require the 2000FAN fan
sled (refer to
).
Installation
To install the Kameleon modules, perform the following steps:
1.
Place the KAM-MIX-R passive rear module in a rear frame slot and
tighten the screws on each side of the rear module.
2.
Install the audio submodule on KAM-DEC-4ADC-MUX module (if
required) and place the front module in the corresponding front slot.
3.
Cable the signal ports.
All Kameleon modules can be inserted and removed from a 2000 Series
Kameleon Frame with power on.
Note
Remove the front processing module before removing the rear I/O module.
Audio submodules must be installed or removed with the front module
removed from the frame (front module powered down).
System Requirements
For proper operation of the KAM-DEC-4ADC-MUX modules, the frame
must be a 2000T1DNG or 2000T3NG which include the following compo-
nents:
•
2000NET module (software version 4.0.0 or later recommended for full
functionality)
•
2000GEN module
•
Dual 130W power supplies in the 2000T1DNG frame
•
Single 240W power supply and 2000FAN in the 2000T3NG frame