KAM-DEC-4ADC-MUX Instruction Manual
Software Updating
11.
In the Client Name list on the right side of the Load Software screen,
find the KAM-DEC-4ADC-MUX modules. Check the corresponding
checkboxes for KAM-DEC-4ADC-MUX modules running version 1.0.4
only in the window on the right to indicate you wish to update these
devices. For updating modules running version 5.0.2 or later, go to
.
CAUTION
All Kameleon type modules will also appear in the list of Client Names, do not
attempt to download this first .fld software to any module but a
KAM-DEC-4ADC-MUX module at version 1.0.4.
12.
Check the
Re-Boot when complete
checkbox in the lower left corner of the
screen.
13.
Click on the
Load
button at the bottom of the Load Software screen to
begin the update.
14.
If the load has been successful, a popup will appear as shown in
. Click the
OK
button.
Figure 44. Load Successful Popup
15.
Allow the reboot to complete.
16.
Open the Status web page of each module. The Status web page will
show the front module in a red FAULT condition. Check that the
software version at the bottom of the screen has been updated to
version 5.0.2.
17.
Bring up NetConfig again and click on the
Discover
button in the top
menu bar. Then click on the
Load SW
button.