38
UCP
-
3901 Card Installation and Operation
User Interface
User Interface
Control options
The UCP
-
3901 can be controlled in the following ways:
• The local control panel and its push-buttons can be used to move through a menu of
parameters and to adjust parameter values (see section
Local control using the Densité
frame control panel to set the Card’s IP Addresses
• Grass Valley’s GV Orbit can be used to access the card’s operating parameters from a
remote computer, using a convenient graphical user interface (GUI). The initial setup
can be made through RollCall; see
Local control using the Densité frame control panel to set the
Card’s IP Addresses
Only make changes to the Ethernet settings during off hours as any settings change will
take the card offline for up to 30 seconds.
Push the SELECT button on the UCP
-
3901 card edge (see
page 27) to assign the local control panel to operate the UCP
-
3901.
• The STATUS LED on the UCP
-
3901 card edge flashes yellow.
Use the control panel buttons to navigate through the menu. The menu allows you to view
and set the UPC
-
3901 card’s current:
•
MANAGEMENT
Ethernet port IP address that you use in RollCall to connect to the card.
See also
•
SFP1
and
SFP2
Ethernet port IP addresses that you use for media streams. See also
The Ethernet port configuration parameters are:
• The Ethernet port’s current operating mode: DHCP or DISABLE.
• The Ethernet port’s current IP Address: when mode is set to DISABLE, set the card’s IP
address.
• The Ethernet port’s current subnet Mask: when mode is set to DISABLE, set the subnet
mask for your network.
• The Ethernet port’s current default Gateway: When mode is set to DISABLE, set the
network switch’s IP address.
The UCP
-
3901 Card will reboot once you have changed a network parameter when:
• Densité local control is removed from the card or,
• You navigate back to the top level menu. You can change all network parameters in one
shot (without the unit rebooting for every parameter change) by staying at a menu
level lower than the top level menu (stay within the NETWORK SETTINGS menu level or
lower) when changing the network settings.
A reboot takes approximately 75 seconds. Two versions of the local control panel exist:
Содержание IQUCP25
Страница 8: ...8 Notices ...
Страница 47: ...47 UCP 3901 User Manual IQUCP2504 2B3 IQUCP2505 3B3 IQUCP5000 2B3 ...
Страница 48: ...48 IQUCP Card Installation and Operation Rear Panel and Connectors IQUCP5001 3B3 IQUCP5002 2B3 IQUCP5003 3B3 ...
Страница 52: ...52 IQUCP Card Installation and Operation Remote control using RollCall ...
Страница 58: ...58 Connections and Cabling About HDMI Type Signal Connections ...
Страница 70: ...70 Connecting to the Card s Configuration Interface Setting Values in RollCall ...
Страница 167: ...167 UCP 3901 User Manual Ethernet Arcnet Not currently used ...
Страница 246: ...246 MADI Processing SDC Ethernet Arcnet Ethernet Arcnet Not currently used ...
Страница 308: ...308 Multiviewer SDC Timer Request Protocol ...