RollCall Control Panel
Logging - Spigot
Brought into line with UCP V16.0
The following options are available. Enable check boxes to activate log fields as required.
Note:
If spigots are linked for UHD traffic, only the Master spigots are shown
on the main menu. Slave spigots are not shown.
Log Field
Description
INPUT_
N
_IDENT=
System-defined identifier for the input, based on the rear
ID.
INPUT_
N
_NAME=
Name of the input, as defined by the user on the
Setup
page. See
INPUT_
N
_STATE=
Valid values are:
•
OK
: input signal good.
•
FAIL
: input signal not detected.
INPUT_
N
_TYPE=
HD/SD/3G SDI
INPUT_
N
_STANDARD=
PAL/NTSC/625 Mono/525 Mono
INPUT_
N
_STREAM=
Not to be used if the spigot is part of a UHD Quad-Link
configuration. Use INPUT_
N
_LINK_
M
_
STATUS= in this case (see below).
Displays whether an IP sender uses SDI on Primary,
Secondary or both. Valid values are:
•
Dual
- both used.
•
A
- only Primary used.
•
B
- only Secondary used.
INPUT_
N
_LINK_
M
_
STATUS=
Reports the status of an input when it is used as a QL UHD
link. Valid values are:
• OK: Linked
• OK: Not Linked
• FAIL: No Input
• FAIL: Wrong Standard
OUTPUT_
N
_IDENT=
Name of the output as shown on the rear panel.
OUTPUT_
N
_NAME=
Name of the output as defined by the user.
OUTPUT_
N
_STATE=
Valid values are:
•
OK
- output signal good.
•
FAIL
- output signal not detected.
• WARN:Freeze
• WARN: Pattern
• WARN:Black
Содержание IQMIX25 Series
Страница 14: ...xiv Notices...
Страница 17: ...xvii IQMIX25 40 User Manual Ethernet Arcnet 93 Interop Page 94 SFP Configuration Page 96 Contact Us 97...
Страница 18: ...xviii Table of Contents...
Страница 22: ...22 Introduction Rear Panel View IQMIX4011 3B3 IQMIX2500 2B3 IQMIX2501 3B3...
Страница 26: ...26 Introduction Enclosures...
Страница 30: ...30 Connections SFP Link LED Indicators...
Страница 32: ...32 Card Edge LEDs...
Страница 98: ...98...