IQDMX01/03/11/13
B5
IQDMX01OPS 05/04/07
www.snellwilcox.com
Version 1 Issue 12
B5.64
ROLLCALL LOG FIELDS
*Note that these log values are either for future use or may be logged during a transitional state whilst
acquiring or loosing an input signal. It is very unlikely that these states and the associated log values will
become permanent.
Log Field
Log Value
Description
INPUT=
OK
ERR*
LOST
Valid input signal
Invalid input signal
Input signal lost
STD=
UNKNOWN*
STDERR
525
625
Input signal standard not recognized or no signal
Not a selected input standard
Input standard 525
Input standard 625
INPUT1=
OK
ERR*
LOST
Valid input signal
Invalid input signal
Input signal lost
STD1=
ERR
525
625
Not a selected input standard
Input standard 525
Input standard 625
INPUT2=
OK
ERR*
LOST
Valid input signal
Invalid input signal
Input signal lost
STD2=
ERR
525
625
Not a selected input standard
Input standard 525
Input standard 625
EDH=
NONE
FAIL
OK
RESET
The unit is not locked to the input signal
EDH errors have been found on the input signal
No EDH errors found on the input signal
EDH statistics have been reset
ERRSEC=
Runtime string The time since EDH was reset in seconds
ROL_STATES=
OK
FAIL
RollTrack message sent and received OK
RollTrack message not acknowledged
DEEMBED_1=
NONE
OK
Nothing present on pair 1
Embedded pair 1 present on selected SDI input
DEEMBED_2=
NONE
OK
Nothing present on pair 2
Embedded pair 2 present on selected SDI input
DEEMBED_3=
NONE
OK
Nothing present on pair 3
Embedded pair 3 present on selected SDI input
DEEMBED_4=
NONE
OK
Nothing present on pair 4
Embedded pair 4 present on selected SDI input
DEEMBED_5=
NONE
OK
Nothing present on pair 5
Embedded pair 5 present on selected SDI input
DEEMBED_6=
NONE
OK
Nothing present on pair 6
Embedded pair 6 present on selected SDI input
DEEMBED_7=
NONE
OK
Nothing present on pair 7
Embedded pair 7 present on selected SDI input
DEEMBED_8=
NONE
OK
Nothing present on pair 8
Embedded pair 8 present on selected SDI input
NPCM_1=
NONE
OK
Non-PCM not present on pair 1 of selected SDI input
Non-PCM present on pair 1 of selected SDI input
NPCM_2=
NONE
OK
Non-PCM not present on pair 2 of selected SDI input
Non-PCM present on pair 2 of selected SDI input
NPCM_3=
NONE Non-PCM not present on pair 3 of selected SDI input