![GRASS VALLEY IQDMX01 Скачать руководство пользователя страница 56](http://html.mh-extra.com/html/grass-valley/iqdmx01/iqdmx01_user-manual_2257780056.webp)
IQDMX01/03/11/13
B5
IQDMX01OPS 05/04/07
www.snellwilcox.com
Version 1 Issue 12
B5.56
◀
◀
◀
◀
Blanking
This item allows the Vertical Interval data (all or
specific lines) contained in the input signal to be
blanked or passed through the module.
VI Pass 525...
VI Pass 625...
Hanc Blank
V Flag (OBD)
Blanking
◀
VI Pass 525
This item allows lines 11 to 21 and lines 274 to
283 of 525 line signals to be selected and either
passed (highlighted) to the output or blanked from
the output.
VI Pass 525
Blank All
Line 11
to
Line 21
Pass All
Line 274
to
Line 283
◀
Blank All
Selecting this item will select all vertical interval lines in
the 525 line list and blank them from the output.
Pass All
▶
▶
▶
▶
Selecting this item will select all vertical interval
lines in the 525 line list and allow them to passed
through to the output.
VI Pass 625
Blank All
Line 7
to
Line 23
Pass All
Line 320
to
Line 335
◀
VI Pass 625
This section allows lines 7 to 23 and lines 320 to 335
of 625 line signals to be selected and either passed
(highlighted) to the output or blanked from the output.
◀
Blank All
Selecting this item will select all vertical interval lines in
the 625 line list and blank them from the output.
Pass All
▶
▶
▶
▶
Selecting this item will select all vertical interval
lines in the 625 line list and allow them to passed
through to the output.
◀
Hanc Blank
When checked all horizontal data will be blanked,
on the input. When unselected, passthrough
operations will not alter audio packets for groups
that the IQDMX01 has not selected for embedding.
In order to allow minimum synchronization delay
the created packets are output first and then the
passthrough groups are placed after the created
streams have been embedded. This means that
passthrough is achieved without altering the input
packet distribution. Passthrough operation has to
take note of marked for deletion packets and these
are removed where possible to ensure that one
does not run out of useable ancillary space.
For details of the HANC Data Handling please
refer to Appendix 2 on page 80.
◀
V Flag (OBD)
This control allows the V(ertical) Flag to be
changed from line 10 (OVD, Optional Video Data)
to line 20 (OBD, Optional Blanking Data).
Un-highlighted selects OVD and highlighted
selects OBD. The default is OVD selected.
Note that this function is only active for 525 line
signals.