8910ADA-M/ST/SR — Instruction Manual
25
Module Configuration
Local or Remote Control
Set the module for Local or Remote control with jumper J4. When set to
LOC/POT (pins 1-2) the module settings are made locally with onboard
jumpers and switches and the hard-wired customer-supplied potentiome-
ters can be used. In LOC/POTmode, configuration from remote control is
locked out.
When LOC/REM
(local and remote) is enabled (pins 2-3), configuration
can be performed using the onboard switches, jumpers, and/or the web
browser or Newton Control Panel. When local settings are changed by the
remote control, the yellow
OVR
LED will illuminate if the remote settings
are different than the local ones.
Note
The hard-wired potentiometers only work in LOC/POT mode.
Output Mode Select
Use jumper P1 to select the output mode for Channel 1 and Channel 2 as
follows:
•
CHAN 1 Output
•
Input 1 – pins 1-2
•
Input 2 – pins 3-4
•
Sum 1 + 2 – pins 5-6
•
CHAN 2 Output
•
Input 1 – pins 7-8
•
Input 2 – pins 9-10
•
Sum 1 + 2 – pins 11-12
Phase Inversion
Use jumpers J2 and J3 to set Normal or Inverted input phase as follows for
each channel:
•
CHAN 1 Phase, Jumper J2
•
Invert – pins 1-2
•
Normal – pins 2-3
•
CHAN 2 Phase, Jumper J3
•
Invert – pins 1-2
•
Normal – pins 2-3