6026 Series Quick Setup Guide 

 

Ethernet Comms Setup 

 

Note: IP address

 

must match database configuration. 

 

Change IP details from default values before connecting to a real network: 

 

1.

 

Using a PC configured to be on the same subnet as the panel default address, connect to the 
panel. 

2.

 

Open a web browser, type the default IP address 

192.168.1.1 

and press 

Return

.

 

 

 

3.

 

In the Control Panel Setup screen that displays in the browser, type the new control  panel  IP  address, 
subnet mask, and gateway. 

4.

 

Type the Nucleus controller IP addresses and port numbers. Controller port numbers  must  be  greater 
than 1024 (excluding 3000). 

5.

 

Click 

Submit Settings

6.

 

Click 

Reset Control Panel

Key Brightness 

 

Hex switch 2 sets the brightness of the keys.  
0 = minimum brightness, through to 
7 = maximum brightness 
(Switch settings 8 - F are not used)

Содержание 6026 Series

Страница 1: ...6026 Series 2U Control Panels Quick Setup Guide ...

Страница 2: ... Panel Equivalent 6026778 6277 20 40 Multi bus Panel Equivalent 6026777 6277 60 80 Multi bus Panel Equivalent LCD Control Panel 6026783 The LCD panel has a 64x32 pixel LCD on each key and a single rotary encoder The LCD panel is compatible with Aurora control systems ...

Страница 3: ... mimic 1 6 Control System 6026777 and 6027778 panels on a Nebula controller All other panel types and controllers 10 Communications RS485 Ethernet 1 Not currently used Step 3 Connect Power Plug cable into 2A fused IEC socket Step 1 Select Control System Control panel modes are set using DIP switch 6 See table below Step 2 Select Comms Type Set DIP switch 10 UP RS485 serial DOWN Ethernet Step 4 Set...

Страница 4: ...rop address must match database configuration Set DIP switches 1 and 2 down to terminate long cable runs or the end of a multi drop chain Hex Switch 1 sets the multi drop address Switch 1 2 3 4 5 6 7 8 9 A B C D E F 0 Address 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ...

Страница 5: ...browser type the default IP address 192 168 1 1 and press Return 3 IntheControlPanelSetupscreenthatdisplaysinthebrowser typethenewcontrol panel IP address subnet mask and gateway 4 TypetheNucleuscontrollerIPaddressesandportnumbers Controllerportnumbers must be greater than 1024 excluding3000 5 Click Submit Settings 6 Click Reset Control Panel Key Brightness Hex switch 2 sets the brightness of the ...

Страница 6: ...530 478 4148 To obtain a local phone number for the support center nearest you please consult the Contact Us section of Grass Valley s website www grassvalley com An online form for e mail contact is also available from the website Corporate Head Office Grass Valley 3499 Douglas B Floreani St Laurent Quebec H4S 2C6 Canada Telephone 1 514 333 1772 Fax 1 514 333 9828 www grassvalley com ...

Отзывы: