Configuration and Connection
Step 1: Select Control System
Control panel modes are set using DIP switch 6. See table below:
DIP Switch Configuration
Note: DIP switches not identified below can be set either up or down.
DIP switches configure the Control
System, Communications Type, and
GPIO Override.
DIP Switches
Switch
Function
Switch
Position
Up
Down
3
GPIO—Overrider Input Normal Button mimic[1]
6
Control System
6026777 and 6027778
panels on a Nebula
controller
All other panel types and
controllers
10
Communications
RS485 Ethernet
[1]
Not currently used
Step 3: Connect Power
Plug cable into 2A fused IEC
socket
Step 1: Select Control System
Control panel modes are set using DIP switch 6.
See table below
Step 2: Select Comms Type
Set DIP switch 10:
UP = RS485 (serial)
DOWN = Ethernet
Step 4: Setup Comms
Connect the appropriate cable to a comms port (serial or Ethernet) and configure the port address
-
Standard RS232/485 pinout Serial Cable
-
Standard CAT-5 10/100 BASE-T straight-through or crossover Ethernet cable