6-6
Chapter 6 TROUBLESHOOTING
HP-GL™ Command Mode Error Messages
Error message
Cause
Solution
ERROR 1 Instruction
not recognized
An unrecognizable instruction was executed.
Execute a recognizable command.
Noise was input to the plotter upon execution
of the software application.
Press the [ENTER] key.
The software's output settings have been
changed.
Con
fi
gure the software for output by this
plotter.
Ensure that the software's interface settings
are correctly set.
The plotter's interface settings have been
changed.
Ensure that the plotter's interface settings
are correctly set.
ERROR 2 Wrong number
of parameters
A command was executed with the wrong
number of parameters.
Execute the command with the correct
number of parameters.
ERROR 3 Out of range
parameters
A command containing an unusable
parameter was speci
fi
ed.
Execute the command with its parameters
speci
fi
ed within their permissible ranges.
ERROR 5 Unknown
character set
An unrecognizable character set was
speci
fi
ed.
Specify a recognizable character set.
ERROR 6
Position overflow
A command was executed with coordinate
data that exceeds the effective cutting/
plotting area.
Execute the command with its coordinate
data speci
fi
ed within the effective cutting/
plotting area.
ERROR 7
Buffer overflow
The data being input exceeded the capacity
of the plotter's downloadable character
buffer, polygon buffer, etc.
Increase the buffer size.
ERROR 10 Invalid
I/O output request
During execution of an output command,
another output command was executed.
Check the program.
ERROR 11 Invalid
byte following ESC.
The ESC character was followed by an
invalid byte.
Check the program.
ERROR 12 Invalid
byte in I/O Control
A device control command containing an
invalid byte was received.
Check the program.
ERROR 13 Out of
range I/O parameter
A parameter outside of the permissible
numeric range was speci
fi
ed.
Check the program.
ERROR 14 Too many
I/O parameters
Too many interface-related command
parameters were received.
Check the program.
ERROR 15 Error in
I/O transmission
A framing error, parity error or overrun error
occurred.
Change the RS-232C transmission
conditions.
ERROR 16 I/O buffer
overflow
The interface buffer over
fl
owed.
Change the RS-232C transmission
conditions.
Содержание CUTTING PRO FC2250 Series
Страница 1: ...USER S MANUAL MANUAL NO FC2250 UM 151 FC2250 SERIES CUTTING PRO www delinit by...
Страница 104: ...5 29 Chapter 5 FUNCTION SETTINGS AND OPERATIONS Cutting Plotting Conditions List...
Страница 110: ...CHAPTER 6 TROUBLESHOOTING PRODUCT SUMMARY 6 1 Troubleshooting 6 2 Error Messages www delinit by...
Страница 120: ...CHAPTER 8 SPECIFICATIONS PRODUCT SUMMARY 8 1 Main Specifications 8 2 External Dimensions...
Страница 129: ...www delinit by...