Wiring Diagram for Automatic Gate Operator Control
IPI-101
Ethernet
not used
not used
GND
GND
485_B
485_A
GND
Unlock Input
Monitor Input
NC
NO
COM
Press to Exit Button
to open driveway gate
connected to Intercom
Automatic Gate
Motor Control
Board
12VDC Output
GND
Open Light
+
+
+
-
-
-
-
Option 1 to monitor if gate
is open, Relay with coil
voltage to match Open Light
Output
Coil
Option 2 to monitor if
gate is open, Magnet-
ic Position Sensor for
Driveway Gate if pre-
ferred
Note: The Open Light output of an automatic gate operator must be set so it provides output when ever the gate is open
and any timer set to a minimum. If there is an open indicator output on the control board, use this as it will be more
accurate. The monitor connection output may need to have NO and NC terminals swapped around depending on open/
close status of the gate/door.
Gate
or Door
Output
NO
NC
NO
NC
NO
COM
Open/Close Input
Note: Power for the IPI-101 is taken
from the Automatic Gate Operator.
If the gate operator doesn’t have a
12VDC output then any voltage up to
28VDC is ok so long as it doesn’t ex-
ceed 28VDC actual voltage reading.
If higher then a 24V to 12V converter
should be used.
12VDC Input