Grant's Automation
AN1808-12M
4G
Audio Intercom (E2.2)
13/16
17
SMS reply notice of Relay status 894+X#
X=0 (disable SMS reply)
X=1 (enable SMS reply)
0
18
Dial tone volume
898+X#
X=1~3 ( levels)
2
19
Set Egress Pin output relay
900[X]#
X=0 (relay 1)
X=1 ( realy2)
0
20
Set Detect pin output relay
(Detect Pin is egress mode)
901[X]#
X=0 (relay 1)
X=1 ( realy2)
1
21
Detect pin on PCB setup
902[ X]#
X=0~3
0:disable
1:egress mode (901)
2:trigger
3.
Resistance=10KΩ(7.5K~13K)
0
22
Emitting bleep when correct PIN
code entered
903+X#
X=0 (disable)
X=1 (enable)
1
23
Intercom moving Detection
(Theft Proof)
904[X]#
X=0 (disable)
X=1 (enable)
0
24
Set Alert phone number
(moving & trigger)
905[ Y ][ phone number ] #
Y= phone number 1,2 or 3
Phone number=3~15 digits
None
25
Intercom LED light
(optional LED board installed)
906[X]#
X=0 (disable)
X=1 (enable)
0
26
Enable or disable IN1
907[X]#
X=0 (disable)
X=1 (enable)
0
27
Change the length of open code
940[X]#
X=1 (1 code open code)
X=2 (2 codes open code)
1
28
Change open codes of relay 1&2
including trigger / hold / release
for independent apartment
93[X]*[ABCDEF]#
X= apartment number
A,B,C,D,E,F= 0~9 and *
A= trigger relay 1
B= hold relay 1
C= release relay 1
D= trigger relay 2
E= hold relay 2
F= release relay 2
1
code
2
code
1
2
3
4
5
6
10
20
30
40
50
60
29
Send SMS message
(when Detect Pin is triggered)
*26*[ password ] #[content]
Password=setting password
content= up to 100 characters
Detect PIN
Trigger
30
Send SMS message
(when Intercom is moved)
*27*[ password ]#[content]
Password=setting password
content= up to 100 characters
Case open
31
Send SMS message
(when external power is off )
*28*[ password ]#[content]
Password=setting password
content= up to 100 characters
Power loss