4  AFTER SALES

 SUPPORT

If your boiler breaks down during the guarantee period, in the first 

instance you should contact your installer to identify the cause of 

the problem and if necessary your installer will contact us. 
If you are unable to contact your installer please telephone the 

Grant Service Department for assistance. Authorisation to carry 

out guarantee repairs must be obtained from Grant before any 

work is carried out.
Costs incurred by unauthorised work will not be covered by Grant.
To contact the Grant customer support team, please call: 00353 

5791 20089.   
If you need to contact Grant, please have the following 

information available:
• 

The address at which the installed boiler is located and the 

name of the householder.

• 

Details of the fault and any checks you may have carried out.

• 

Details of the installer and any competent persons who may 

have carried out work on the install in the past (if possible)

The completed Boiler Passport, which must have the relevant 

section returned on installation to activate the warranty, with the 

annual service details recorded as appropriate.

Seciton 3: Caring for your Boiler & Section 4: After Sales Support

3.6 

FROST PROTECTION

Your installer may have fitted a frost thermostat. If not and you 

are likely to be away for a short time, leave the boiler on with the 

boiler thermostat set at a low setting.
If the boiler is not going to be used for longer periods of time, the 

boiler and system should be drained.

Contact your service engineer for draining and filling the system.

! NOTE !

We recommend that both antifreeze and corrosion inhibitor 

be used in the primary water system.

3.7 

FAILURE OF ELECTRICITY

 SUPPLY

If the electricity supply fails, the boiler will not operate. It should 

relight automatically when the supply is restored.

If a programmer is fitted, it will retain the time settings for up to 24 

hours and will not have to be reset to the correct time of day when 

the supply is restored.
The programmer display will remain for up to 1 hour in the event 

of an electricity supply failure, and will re-appear when the supply 

is restored.

3.8 

CLEANING YOUR BOILER

Lightly wipe over the case with a damp cloth and a little detergent 

and dry completely. 
Do not use abrasive pads or cleaners.
Take care not to touch any hot surfaces.

Содержание VORTUT15-26

Страница 1: ...IRL DOC 0028 Rev 01 00 October 2022 Grant Vortex Utility Condensing Oil Boiler Range User Instructions...

Страница 2: ...x Low NOx and Blue Flame boilers DOES NOT comply with ErP requirements or EU regulations and as a result Grant does not condone its use If your boiler uses Bio Kerosene B30K refer to the installation...

Страница 3: ...If your boiler fails to light 5 2 3 Turning off your boiler 5 2 4 About your fuel 5 2 5 Boiler controls 5 2 6 Heating system controls 6 2 7 Electricity supply 6 3 CARING FOR YOUR BOILER 6 3 1 Checking...

Страница 4: ...ithin 30 days of its installation To register your boiler please ensure the completed boiler passport is returned to Grant or visit the Grant website www grant eu Your installer may have registered th...

Страница 5: ...itch to OFF To restart simply set the switch to On For long periods Set the On Off switch to OFF and switch off the electricity supply to the boiler If required the fuel supply valve may be closed and...

Страница 6: ...he radiator As the correct operation of a TRV is based on it sensing the air temperature of the room it is fitted in take care not to cover the TRV head with curtains furniture etc Refer to the manufa...

Страница 7: ...person should always be undertaken 3 4 VENTILATION Unless your boiler is installed with a balanced flue system you will require ventilation openings in your property to provide your boiler with a fres...

Страница 8: ...ith the annual service details recorded as appropriate Seciton 3 Caring for your Boiler Section 4 After Sales Support 3 6 FROST PROTECTION Your installer may have fitted a frost thermostat If not and...

Страница 9: ...Signature Service 4 Date Engineer Company name Telephone number OFTEC Technician number Comments Signature Service 5 Date Engineer Company name Telephone number OFTEC Technician number Comments Signa...

Страница 10: ...ce 12 Date Engineer Company name Telephone number OFTEC Technician number Comments Signature Service 13 Date Engineer Company name Telephone number OFTEC Technician number Comments Signature Service 1...

Страница 11: ...Page 11 Notes NOTES...

Страница 12: ...GRANT ENGINEERING IRELAND ULC Crinkle Birr Co Offaly R42 D788 Ireland Tel 353 0 57 91 20089 Email info grantengineering ie www grant eu...

Отзывы: