5
White system
High level and vertical concentric
balanced flue kit- components available:
•
Extensions 225 mm, 450 mm, 950 mm
•
Adjustable 275 to 450 mm
•
Vertical concentric balanced flue kit
•
Extensions 225 mm, 450 mm, 950 mm
•
Adjustable extension 275 to 450 mm
•
45° elbow
Red system (15/21 and 15/26 only)
A flexible vertical balanced flue system
designed to be fitted inside an existing
masonry chimney.
Consisting of three sections:
•
Concentric white painted flue pipe
connected to the boiler
•
Vertical concentric flexible flue
(flexible stainless steel flue liner
inside a flexible plastic air inlet liner)
•
Terminal assembly for chimney top
mounting
Flue extensions and 45° elbows from
the White system may be used.
Fitting instructions for the Low level,
High level and Vertical balanced flue
systems are supplied with the kits.
1.3 Boiler Components
All burners are pre-set for use with
kerosene and are supplied ready to
connect to a single pipe fuel supply
system with a loose flexible fuel line and
3
/
8
" to
1
/
4
" BSP male adaptor supplied
with the boiler.
If required, an additional flexible fuel
line (600 mm) and
3
/
8
" to
1
/
4
" BSP male
adaptor are available to purchase
from Grant UK, for two-pipe oil supply
systems, Part No. RBS104.
The temperature of the water leaving the
boiler to heat the radiators and hot water
cylinder is User adjustable.
Introduction
The boiler is fitted with an overheat
thermostat (which allows it to be used on
a sealed central heating system) which
will automatically switch off the boiler if
the heat exchanger exceeds a pre-set
temperature of 111°C ± 3°C.
The Kitchen/Utility boiler control panel
is fitted with an ON/OFF switch, boiler
thermostat control knob and the manual
reset button for the overheat thermostat.
An optional plug-in programmer is
available to purchase from Grant
UK which allows the User to set the
operating times for central heating and
hot water, Part No. EPKIT.
To access the controls remove the front
panel (pull the panel forward at the top,
then lift off) as shown in Fig. 1.1.
The Boiler House dual thermostat, on
top of the boiler, is fitted with a boiler
thermostat control knob and the manual
reset button for the overheat thermostat.
The controls are shown in Fig. 1.2.
Figure 1-1:
Boiler controls (Kitchen/Utility model shown)
Figure 1-2:
Boiler House dual thermostat (on top of boiler)
OVERHEAT
RESET
HEATING
TEMPERATURE
ON
BOILER
OFF
Lock-out button
Front panel removed (pull forward at top, then lift off)
Front panel fixing clips
Front panel bottom locating tags
G
RA
NT
Programmer
(if fitted)
Pressure gauge
(System models only)
Boiler
thermostat
Overheat
thermostat
reset button
(under cover)
On/Off
switch
SYSTEM PRESSURE
HEATING
TEMPERATURE
OVERHEAT
RESET
BOILER
OFF
ON
Mains On neon
Boiler thermostat
Overheat thermostat
reset button (under plastic cap)