8
Grant Vortex Oil Boilers
Notes:
1
The data given above is approximate only and is based on the boiler being used with a low level balanced flue.
2
The above settings may have to be adjusted on site for the correct operation of the burner.
3
Gas Oil is not suitable for use with the Grant Vortex boiler range.
4
When commissioning the air damper must be adjusted to obtain the correct CO
2
level.
5
* Factory settings.
6
The combustion door test point may be used for CO
2
and smoke readings only. Do not use this test point for temperature
or efficiency readings.
Flue gas analysis
To allow the boiler to be commissioned and serviced, the boiler is supplied with a combustion test point on the front
cleaning door. When this test point is used please note the following:
1.
The test point is for CO
2
and smoke readings only.
2.
The boiler efficiency and temperature must be taken from the flue test point on high level, vertical and conventional
flue adaptors.
3.
Concentric low level flues do not contain a test point. The temperature and efficiency readings must be taken from the
flue terminal.
3 - BOILER TECHNICAL INFORMATION
Note: Grant Vortex boilers are only for use with kerosene.
Grant Vortex oil boilers using Class C2 kerosene
3.3
(kW)
15.0
20.0
23.0
26.0
26.0
31.5
36.0
36.0
41.5
46.0
46.0
52.0
58.0
58.0
64.0
70.0
(Btu/h)
51 180
68 240
78 475
88 700
88 700
107 500
123 000
123 000
142 000
157 000
156 952
177 424
197 896
197 896
218 368
238 840
Nozzle
0.50/80°EH
0.60/80°EH
0.65/80°EH
0.75/80°EH
0.75/80°EH
0.85/80°EH
1.00/80°EH
1.00/80°EH
1.20/80°S
1.25/80°S
1.25/80°S
1.35/80°S
1.65/80°S
1.65/80°S
1.65/80°S
1.75/80°S
Oil
press.
(bar)
7.0
8.0
8.5
8.0
8.0
9.0
9.1
9.0
8.0
8.0
8.0
9.5
8.0
8.0
9.5
9.5
Smoke
No.
0 - 1
0 - 1
0 - 1
0 - 1
0 - 1
0 - 1
0 - 1
0 - 1
0 - 1
0 - 1
0 - 1
0 - 1
0 - 1
0 - 1
0 - 1
0 - 1
Fuel flow
rate
(kg/h)
1.25
1.67
1.94
2.16
2.18
2.57
3.01
3.01
3.56
3.90
4.01
4.47
5.05
5.05
5.58
6.01
Flue gas
temp.
(° C)
60 - 65
65 - 70
70 - 75
75 - 80
65 - 70
70 - 75
75 - 80
75 - 80
80 - 85
85 - 90
75 - 80
75 - 80
75 - 80
75 - 80
75 - 80
75 - 80
CO
2
(%)
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
Burner
head type
T1
T1
T2
T2
T3
T3
T3
T5
T5
T5
GIB
GIB
GIB
GIB
GIB
GIB
Heat Output
15/26
Riello RDB1
26/36
Riello RDB2
36/46
Riello RDB2.2
46/58
Riello RDB3.2
58/70
Riello RDB3.2
Model and
burner type
*
*
Sealed system data
-
System models (not 46/58 and 58/70)
3.2
*
Heating system pressure (cold)
Operating pressure of pressure relief valve
Expansion vessel size (15/26)
Expansion vessel size (26/36)
Expansion vessel size (36/46)
Max heating system volume (including boiler) (15/26)*
Max heating system volume (including boiler) (26/36)*
Max heating system volume (including boiler) (36/46)*
Cold water mains connection
Pressure relief valve discharge connection
Maximum 1.0 bar, Minimum 0.5 bar
2.5 bar
10 litres (pre-charged at 1 bar)
12 litres (pre-charged at 1 bar)
16 litres (pre-charged at 1 bar)
106 litres (approximately)
128 litres (approximately)
170 litres (approximately)
15 mm copper pipe
15 mm copper pipe
* Based on vessel charge and system cold fill pressure of 0.5 bar
*
*
SEDBUK
efficiency
(%)
95.0
97.0
92.6
94.1
93.6
Burner
head setting
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
0
0
0
0
0
4