8
Electrical Safety Tests
With the unit disconnected from the
AC power supply, and the power supply lead
plugged into the unit, perform the following
safety tests before returning the unit to the
customer.
8.1 Earth
Bonding
Test
Use a low resistance measuring
instrument to check that the resistance
between unit chassis and power cable earth
connector is less than 0.1 ohm.
8.2
Insulation Resistance Test
Set power switch to ON, and check
that cut out is reset by pressing reset button.
Connect the live and neutral pins of the
power supply plug together. Use a 500V
insulation resistance tester and measure the
insulation resistance between the earth and
live/neutral pins. This should be greater than
10 Mohm.
9 Final
Inspection
a) Check that wiring is not trapped or nipped.
b) Check that the over temperature cut-out
bulb has been fitted correctly to the heater.
c) Check that cut-out has been correctly
screwed to the front panel and reset button
operates smoothly.
d) When re-fitting the cover ensure that the
earth wire is connected. Gently shake unit to
ensure there are no loose items left within
the unit.
GD100/GD120
Part No. 17592/Issue 1
July 2002
Page 16
Содержание OPTIMA RANGE GD100
Страница 25: ...B x4 A C Fig 7 Fig 8 Fig 9 GD100 GD120 Part No 17592 Issue 1 July 2002 Page 25 ...
Страница 26: ...D E x2 F PCB Clip D Fig 10 Fig 11 Fig 12 GD100 GD120 Part No 17592 Issue 1 July 2002 Page 26 ...
Страница 27: ...N P H Fig 13 Fig 14 Fig 15 Heater wires Cutout Bulb G GD100 GD120 Part No 17592 Issue 1 July 2002 Page 27 ...
Страница 28: ...Part No 17592 Issue 1 July 2002 Fig 16 J K x4 L Fig 17 M M M Fig 18 Page 28 ...
Страница 30: ......
Страница 31: ......