2
Technical Specifications
T
echnical
Specifications
DuoWave Plus Open Vented Cylinder Details
1
17
18
19
2
3
4
5
6
13
7
8
9
10
12
11
Item
Description
Connection Size
1
DHW Out
22mm compression
2
T & P valve connection
1
/
2
" BSPF
3
Boiler return tapping
22mm compression
4
Secondary return tapping
22mm compression
5
Boiler dual thermostat pocket
-
6
Boiler flow tapping
22mm compression
7
Solar heat source return
tapping
22mm compression
8
Solar heat source dual
stat pocket (for dual stat only)
-
9
Cold water inlet
22mm compression
10
Solar heat source
flow tapping
22mm compression
11
Immersion heater c/w control
& limit thermostat (factory-fitted)
1
3
/
4
" BSPF
12
Solid fuel (uncontrolled)
flow tapping
28mm compression
13
Solid fuel (uncontrolled)
return tapping
28mm compression
17
Temperature & Pressure relief
15mm compression
valve - 90°C/7 bar
18
Tundish
15/22mm compression
19
Discharge pipe
(not supplied with cylinder)
-
20
Mains water supply pipe
(not supplied with cylinder)
-
21
Drain cock
(supplied with cylinder)
-
Note:
Pipework between items 17 and 18 not supplied with cylinder.
Figure 2-2:
Cylinder connections and controls