Getting started with VSD-E & VSD-XE 160

 

 Manual Ver. 1.10

3.

Setting drive parameters

Follow 

GDtool manual

 for making connection to drive and choose one of the cases below.

Tip:

 if you are getting led blinking sequences #9 or #11 (see VSD-E manual), the HV power supply probably has too 

low power capability. In such case try increasing voltage and/or current limits of PSU.

  

Case A: you have GDtool motor configuration file from supplier

The easiest way to get motor operational is to 

load motor configuration file supplied by motor seller

 (if 

available) to GDtool and drive. See figure below for doing so. 

Note that the settings in typical 

pre-configured files have quite loose position control parameters 

(making 

motor not stiff)

 

and those need to be tuned after motor is mounted on actual machine. We'll return in position tuning in 

the last chapter.

Figure 4: Loading motor configuration to drive after connection to drive has been established.

  

Case B: no pre-configured motor settings file available

If ready configuration file for your motor was not available, follow 

GDtool manual 

and your 

motor datasheet 

for 

motor parameter setting. In case of uncertainty, feel free to contact us for assistance.

After motor parameters are set, you may proceed to drive tuning. Follow the instructions of 

Tuning manual

. Note that 

it is not necessary to tune position controller very well at this point because position mode tuning has to be re-done 

after motor is mounted on actual machine. This is because load on motor will have significant effect in position 

response. We'll return in position tuning in the last chapter.