Compressor Operating Instructions 

 

61099049 

 

 

If  you  have  no  experience  with  such  equipment,  you  should  first  get  assistance  from 
experienced people. 

 

Keep all supplied documents with the equipment for future reference if required. Keep the 
purchase receipt for any warranty claims. 

 

If you lend or sell the equipment, supply all documentation with it. 

 

Observe the operating and maintenance instructions found in this manual. 

 

Maintenance should be performed at the prescribed intervals and in the prescribed scope. 

 

Following  maintenance  work,  all  dismantled  protective  devices  must  be  properly 
reinstalled. The protective devices and their protective functions should be inspected by a 
competent person before using the machine. 

 

Defective equipment must be repaired promptly in order to minimize the extent of damage 
and avoid endangering the safety of the equipment. 

 

The compressor may only be used and operated under the conditions laid down in these 
operating instructions. 

 

Retrofits, changes or modifications to the equipment are strictly prohibited. They require 
consultation with and written approval by the manufacturer. 

 

If during operation (residual) hazards and risks become apparent which are not described 
in this manual, the operator is obliged to report this to the manufacturer. 

 

Do not change the setting of the safety valve. Before each use, check that the equipment 
is functioning properly and that the lines are not leaking. 

 

Compressed air under high pressure can cause severe or fatal injury! If injured contact a 
physician immediately! 

 

Before each use always perform a visual and a function check of the equipment to identify 
damage and worn parts, and arrange for their repair by trained personnel before use. 

 

After opening the packaging check that all components are complete and undamaged. If 
components are missing or damaged, contact your dealer immediately and use the device 
only after approval by the dealer. 

 

Warning: Clogged oil filters or valve failure will result in insufficient lubrication. 

 

Make sure that the oil cooling devices are kept clean and that the protective equipment 
remains in working order. 

 

Warning: All hoses and fittings of road-driven compressors must be suitable for use on 
construction sites at the maximum allowable pressure. 

 

It  is  recommended  that  feed  hoses  be  fitted  with  a  safety  cable,  e.g.  a  wire  rope,  for 
pressures above 7 bar. 

 

The  machine  must  always  be  placed  on  a  level  and  horizontal  surface  and  may  not  be 
tilted. 

 

Содержание 61099049

Страница 1: ...ctions Pump 61099049 These operating instructions must be read thoroughly before use and followed These Operating Instructions must be retained for future reference Translation of the original operati...

Страница 2: ...sor 9 4 3 Operating a pressure tank 10 4 4 Operation at cold temperatures 10 4 5 Operating the equipment 10 4 6 Switching off the compressor 11 5 Maintenance and care 11 5 1 General maintenance instru...

Страница 3: ...the item numbers in the tables Instructions for which the order must be followed are numbered 1 2 3 Lists are marked with bullet points Symbol labels on the device with their meaning Wear hearing pro...

Страница 4: ...operation residual hazards and risks become apparent which are not described in this manual the operator is obliged to report this to the manufacturer Do not change the setting of the safety valve Be...

Страница 5: ...d against the penetration of medium sized foreign bodies from 12 5 mm It is not protected against the penetration of liquids Therefore the equipment must not be used in damp or wet rooms or outdoors i...

Страница 6: ...f using the switch Fig 2 and then disconnected from the mains by pulling the mains plug The compressor can only be prepared for operation by people with sufficient technical expertise All other operat...

Страница 7: ...nstructions for correcting malfunctions in Chapter 8 of this manual Failure to observe the safety instructions can result in damage to property and personal injury Before the compressor is restarted w...

Страница 8: ...ed is clean dry and well ventilated Make sure that the electrical voltage is constant and does not deviate from the prescribed voltage by more than 4 Make sure that the oil level is within the red ind...

Страница 9: ...a good reason and the permissible operating pressure of the compressor should never be exceeded If the permissible operating pressure is exceeded and safety switches and valves are manipulated this c...

Страница 10: ...gularly for damage e g rust If you discover any damage contact your specialist dealer immediately 4 4 Operation at cold temperatures At low temperatures the oil in the crankcase becomes thick and visc...

Страница 11: ...tch off the compressor press down the on off switch see Fig 2 The unit must never be switched off by pulling out the mains plug Pulling out the mains plug without first pressing down the button on the...

Страница 12: ...ional safety of the unit for as long as possible After the first 10 operating hours the crankcase should be cleaned and the oil renewed The oil level Fig 4 no 20 should be checked every 20 operating h...

Страница 13: ...at the bottom of the boiler Drain the condensate at least once a week To do this open the drain screw at the bottom of the boiler Fig 1 no 7 until there is no more water in the air coming out The con...

Страница 14: ...he unit using the transport bracket provided Always store the compressor in a dry and frost proof room If the compressor is not used for a longer period of time switch it off when it is completely dis...

Страница 15: ...g parts worn out 1 Check and re fasten 2 Check and remove foreign body Insufficient pressure build up or reduced ventilation 1 Motor running too slowly 2 Air filter clogged 3 Safety valve leaking 4 Ve...

Страница 16: ...Compressor Operating Instructions 61099049 16 9 Component drawing with installation position Figure 4...

Страница 17: ...be 61099049 16 1 17 O Circlip 18 3x 2 65 O 61099049 17 2 18 Screw M5x16 61099049 18 4 19 Crankcase cover 61099049 19 1 20 Oil level regulator 61099049 20 1 21 M6x10 bolt 61099049 21 1 22 O Circlip 5 6...

Страница 18: ...shaft 61099049 53 2 54 Drain valve 61099049 59 1 55 M8x30 bolt 61099049 54 1 56 Rubber foot 61099049 55 2 57 Nut M8 61099049 56 2 58 Spindle Rp1 2 61099049 57 2 59 Pressure vessel 61099049 58 1 60 Pow...

Страница 19: ...ical equipment EC protection objectives were met according to Annex I No 1 5 1 of the Machinery Directive 2006 42 EC The machine also complies with the 2014 29 EU regulations on simple pressure tanks...

Страница 20: ...700 Postal and shipping address Wilhelm Fricke SE Zum Kreuzkamp 7 DE 27404 Heeslingen 15 Legal Notice Translation of the original operating instructions for a Compressor Model 61099049 Manufacturer W...

Отзывы: