Installation

Figure 1

Wood wall installation

Wood ceiling installation

Concrete wall installation

Concrete ceiling installation

Figure 2

Figure 3

Figure 4

Figure 5

Wall and Ceiling Mount Installation

Installation Steps: 

1.Wood wall and ceiling installation: Drill in the    5 x 40 screws through the appropriate holes in the bracket    
   (figure 2-3)
2.Drywall and ceiling installation: Install the anchors and drill in the    5 x 40 screws into the appropriate 
    bracket holes (figure 4-5)

Take out all the parts from the package and following the accessories guideline ensure all the parts are there. 
There are three different types of installation available for this product: wall mount, ceiling mount or ceiling hang. 
Depending on the installation environment, the floating mounting brackets can be installed at various points for your 
convenience. However, the ideal position for the mounting brackets is closer to the endcap as this will reduce 
vibration and noise.

1.According to the surface of installation, choose the appropriate screws needed for mounting (regular screws for   
   wood surfaces, tapping screws for concrete surfaces)
2.Mount the brackets onto the surface, ensuring it is level (tip: draw a erasable level line when mounting the 
   brackets). See below for picture description (figure 1):

9

How to adjust tension situation of the string

If the string is loose which is caused by bump on transportation or faulty operation (Figure 30), please rotate the 

String Adjustment Knob clockwisely to make string tensional (Figure 31). If the string is over-tensional, please press 

the String Releasing Button and then rotate the String Adjustment Knob counter-clockwisely  to suitable tensional 

situation (Figure 32).

String Adjustment Knob

String Releasing 
Button

Figure 30

Figure 31

Figure 32

Attention:
> Please make sure there is no dust or dirt on the fabric surface before rolling it back to the casing
> The recommened working time is less than 50 seconds. The motor will enter overheating protection 
    status and stop working for every continuous 4 minuters operation, user would need to wait for a while 
    until the motor cool down before operating again.
> There is no lube needed for the motor. Please be noticed that the appropriate setting is optimized 
    which requires no further adjustment, please consult the after sales team before adjusting the limits.