Syslog Level 

Select the GXW4024 to report the log level. Default is NONE. The level is one of DEBUG, INFO, 
WARNING or ERROR. Syslog messages are sent based on the following events: 

1.  product model/version on boot up (INFO level) 
2.  NAT related info (INFO level) 
3.  sent or received SIP message (DEBUG level) 
4.  SIP message summary (INFO level) 
5.  inbound and outbound calls (INFO level) 
6.  registration status change (INFO level) 
7.  negotiated codec (INFO level) 
8.  Ethernet link up (INFO level) 
9.  SLIC chip exception (WARNING and ERROR levels) 
10.  memory exception (ERROR level) 

The Syslog uses USER facility.  In addition to standard Syslog payload, it contains the following 
components: 
 
GS_LOG: [device MAC address][error code] error message 
 

Example

:  May 19 02:40:38 192.168.1.14 GS_LOG: [00:0b:82:00:a1:be][000] Ethernet link is up 

Primary RADIUS 
Server 

IP Address or FQDN of the primary RADIUS Server  

Primary RADIUS 
Auth Port 

Primary Radius server authentication port. Default value is 1812 

Primary RADIUS 
Acct Port 

Primary Radius server accounting port. Default value is 1813 

Primary Radius 
Server Secret 

Special secret string should be preconfigured according to RADIUS Server configuration 

Secondary 
RADIUS Server 

IP Address or FQDN of the secondary RADIUS Server 

Secondary 
RADIUS Auth Port 

Secondary Radius server authentication port. Default value is 1812 

Secondary 
RADIUS Acct Port 

Secondary Radius server accounting port. Default value is 1813 

Secondary Radius 
Server Secret 

Special secret string should be preconfigured according to RADIUS Server configuration 

RADIUS Timeout 

Default value is 2 seconds. The time between retries the GXW will send “Access-Request” 
message to RADIUS server in purpose to authenticate it.   

RADIUS Retry 

Default value is 3 times. Number of times the device will try to authenticate itself with 
preconfigured RADIUS server during initialization process. 

Download Device 
Configuration 

This setting allows user to download a text file containing all the P values of each setting as 
configured on the unit. 

 
 

Содержание GXW-4024

Страница 1: ...GXW4024 User Manual www grandstream com Firmware Version 1 0 1 8 support grandstream com Grandstream Networks Inc Analog IP Gateway GXW4024 24 FXS Ports...

Страница 2: ...RANSFER 12 BLIND TRANSFER 12 ATTENDED TRANSFER 12 3 WAY CONFERENCING 13 HUNTING GROUP 13 INTER PORT CALLING 14 SENDING AND RECEIVING FAX 14 SUPPORT RADIUS PROTOCOL 15 CALL FEATURES 16 CONFIGURATION GU...

Страница 3: ...CALL FEATURES TABLE STAR CODES 16 TABLE 7 BASIC SETTINGS 20 TABLE 8 STATUS PAGE 21 TABLE 9 ADVANCED SETTINGS 22 TABLE 10 FXS PORTS SETTINGS 25 TABLE 11 PROFILE SETTINGS 26 CONFIGURATION GUI INTERFACE...

Страница 4: ...rver profiles caller ID for various countries regions T 38 fax flexible dialing plans security protection SIPS TLS comprehensive voice codec including G 711 a u law G 723 1 G 726 16 24 32 48 kbit s G...

Страница 5: ...net and access the unit s configuration pages 1 Connect standard touch tone analog phones to ANY of the FXS ports 2 Insert the Ethernet cable into the LAN port and connect the other end of the Etherne...

Страница 6: ...LED Indicates Power Remains solid ON when Power is connected and ON Ready LED Remains solid ON if profile registered Blink slowly if not configured or lost registration LAN LED Indicates LAN port acti...

Страница 7: ...4024 CONFIGURATIONS APPLICATION ONE GXW 4024 FXS GATEWAY CONFIGURATION INTERNET CLOUD Anywhere in the world GXW FXS Series 24 Ports Analog Phones FXS Gateway acts as a virtual office connecting analog...

Страница 8: ...ts PSTN PBX analog telephone sets or analog trunks 50 Pin Telco connector for easy Chassis or Rack connection TABLE 3 GXW4024 SOFTWARE FEATURES Telephone Interfaces RJ 11 24 FXS SIP accounts choice of...

Страница 9: ...t on 24 AWG line Caller ID Bellcore Type 1 2 ETSI BT NTT and DTMF based CID Polarity Reversal Wink Yes EMC EN55022 EN55024 and FCC part15 Class B Safety UL HARDWARE SPECIFICATION The hardware specific...

Страница 10: ...007 Preferred Vocoder Enter 9 to go to the next selection in the list PCMU PCMA iLBC G 726 G 723 G 729 010 MAC Address Announces the MAC address of the unit 013 Firmware Server IP Address Announces c...

Страница 11: ...press the or wait for 4 seconds 2 Dial an outside number e g 626 666 7890 first enter the prefix number usually 1 or international code followed by the phone number Press or wait for 4 seconds Check...

Страница 12: ...he flash button First call is placed on hold Press the flash button to toggle between two active calls CALL TRANSFER Blind Transfer Assume that call Caller A and B are in conversation A wants to Blind...

Страница 13: ...ay and have the ability to use all FXS ports to make receive calls Using this feature all ports active in same hunt group will have the same phone number and incoming calls will be distributed in a ro...

Страница 14: ...ID left blank Hunting Group set to 1 FXS Port 4 SIP UserID and Authenticate ID left blank Hunting group set to 2 FXS Port 5 SIP UserID and Authenticate ID left blank Hunting Group set to 1 FXS Port 6...

Страница 15: ...provide redundancy to this feature In case Primary Radius server becomes unusable RADIUS requests will be automatically sent to the secondary server When at least one RADUIS server was configured the...

Страница 16: ...Call Forward Dial 72 and then the forwarding number followed by Wait for dial tone and hang up dial tone indicates successful forward 73 Cancel Unconditional Call Forward Dial 73 and wait for dial ton...

Страница 17: ...et Mask Gateway and DNS server respectively FIRMWARE SERVER IP ADDRESS Select voice menu option 013 to configure the IP address of the firmware server CONFIGURATION SERVER IP ADDRESS Select voice menu...

Страница 18: ...168 1 14 Once the HTTP request is entered and sent from a Web browser the user will see a log in screen There are two default passwords for the login page User Level Password Web pages allowed End Use...

Страница 19: ...nter it on this field If using public IP keep this field blank 2 Use Random Ports under Advanced Settings webpage It really depends on your network settings whether to set this parameter to Yes or No...

Страница 20: ...ield values for the Static IP mode are not used even though they are still saved in the Flash memory The GXW4024 acquires its IP address from the first DHCP server it discovers from the LAN it is conn...

Страница 21: ...ice ID in HEX format This is needed for ISP provisioning or troubleshooting IP Address Shows IP address of GXW4024 Product Model Contains the product model info Software Version Program This is the ma...

Страница 22: ...especially the power supply as this will damage the device Depending on the network environment this process can take up to 15 or 20 minutes Via HTTP or HTTPS Server The URL for the HTTP HTTPS server...

Страница 23: ...e By default the tones are set to North American frequencies Frequencies should be configured with known values to avoid uncomfortable high pitch sounds ON is the period of ringing ON time in ms while...

Страница 24: ...RADIUS Server Primary RADIUS Auth Port Primary Radius server authentication port Default value is 1812 Primary RADIUS Acct Port Primary Radius server accounting port Default value is 1813 Primary Radi...

Страница 25: ...inations for more than one Hunt Group For example Ports 1 3 and 5 may be members of the same hunt group the rest of the ports may have separate numbers and may be reached independently Select appropri...

Страница 26: ...NS SRV resource records indicates how to find services for various protocols NAPTR SRV Naming Authority Pointer according to RFC 2915 One mode can be chosen for the client to look up server The defaul...

Страница 27: ...Send Hook Flash Event Default is NO If set to yes flash will be sent as DTMF event Enable Call Features Default is Yes If Yes call features using star codes will be supported locally Off Hook Auto Dia...

Страница 28: ...e call will be forwarded after this preconfigured amount of time No Key Entry Timeout Default is 4 seconds Call will be completed within this time interval if no additional key entry occurs Early Dial...

Страница 29: ...2 9 x allows international calls starting with 011 3469 11 allow dialing special and emergency numbers 311 411 611 and 911 Note In some cases user wishes to dial strings such as 123 to activate voice...

Страница 30: ...eference list that will be included with the same preference order in SDP message The first Vocoder is entered by choosing the appropriate option in Choice 1 The last Vocoder is entered by choosing th...

Страница 31: ...efault is 200 In 100 1 0000 milliseconds range Hook Flash timing Time period when the cradle is pressed Hook Flash to simulate FLASH To prevent unwanted activation of the Flash Hold and automatic phon...

Страница 32: ...es GAPS uses enhanced NAT friendly TFTP or HTTP thus no NAT issues and other communication protocols to communicate with each individual Grandstream device Grandstream provides GAPS service to VoIP se...

Страница 33: ...f the configured firmware server is found and a new code image is available the GXW4024 will attempt to retrieve the new image files by downloading them into the GXW4024 s RAM During this stage the GX...

Страница 34: ...mplate When Grandstream Device boots up or reboots it will issue request for configuration file named cfgxxxxxxxxxxxx where xxxxxxxxxxxx is the MAC address of the device i e cfg000b820102ab The config...

Страница 35: ...ress for about 10 seconds till the LED off and on and a minor click sound heard 4 Take out the pin and wait for the unit boot up All settings are now restored to factory default IVR Command Reset defa...

Отзывы: