Terminal Block Wired For 400 Volt WYE As Viewed
Through Rear Access Panel
FLW1915N_SVG
L 1 L 2 L 3
N
1
10
10
9
9
9
10
2
3
4
5
6
8
7
1.
Black Wire
2.
Black/White Wire
3.
Black/Red Wire
4.
White Wire
5.
White/Red Wire
6.
White/Black Wire
7.
Green/Yellow Wire
8.
Earth/Ground - Power Cord
9.
230 Volt
10.
400 Volt
Figure 11
Non-Gravity Drain Models - Connect
Drain Hose to Drain Receptacle
Remove the drain hose from its shipping position on the rear of
the washer by removing the shipping tape.
IMPORTANT: Drain receptacle must be capable of han-
dling a minimum of 35 mm [1-3/8 inch] outside diame-
ter drain hose.
Drain Flow Rate
Drain Height
Flow Rate
liters per minute [gal-
lons per minute]
0.9 m [3 ft.]
27.7 [7.3]
1.5 m [5 ft.]
17.8 [4.7]
1.8 m [6 ft.]
13.4 [3.5]
2.1 m [7 ft.]
4.8 [1.3]
2.4 m [8 ft.]
0 [0]
Standpipe Installation
1.
Place the drain hose into the standpipe.
2.
Remove the beaded tie-down strap from accessories bag and
place around standpipe and drain hose and tighten strap to
hold hose to standpipe. Refer to
. This will prevent
the drain hose from dislodging from drain receptacle during
use.
SWD1026N_SVG
2
3
1
1.
610 to 914 mm [24 to 36 in.] Recommended Height
2.
Beaded strap from accessory bag
3.
Standpipe 51 mm [2 in.] or 40 mm [1-1/2 in.]
Figure 12
Installation
©
Published by permission of the copyright owner -
DO NOT COPY or TRANSMIT
19
Part No. 805898ENR1