Grand Seiko 9SA5 Скачать руководство пользователя страница 14

Magnetic resistance (Magnetic influence)

Affected by nearby magnetism, a watch may temporarily gain or lose time or stop operating.

Indication on the case

back

Conditions of use

Certified level

Keep the watch more than 5 cm away

from magnetic products.

4,800 A/m

Keep the watch more than 1 cm away

from magnetic products.

16,000 A/m

MAGNETIC RESISTANT

40000A/m

The watch can maintain its

performance in most cases where it is

brought close to (at least 1 cm spaced

from) magnetic products not only in

normal daily life circumstances but

also in a special work environment.

40,000 A/m

 * A/m (ampere meter) is the international unit (SI unit) for indicating the magnetic field.
If the watch becomes magnetized and its accuracy deteriorates to an extent exceeding the specified

rate under normal use, the watch may need to be demagnetized. In this case, you will be charged

for demagnetization and accuracy readjustment even if it happens within the guarantee period.

Examples of common magnetic products that may affect watches

The reason why this watch is affected by magnetism

The built-in balance spring is provided with a magnet, which may be influenced by a strong external

magnetic field.

Smartphone, cellular phone, tablet terminal

(speaker, magnet of cover)

AC adapter

Bag

(with magnet

buckle)

AC-powered

shaver

Magnetic

cooking device

Portable radio

(speaker)

Magnetic

necklace

Magnetic health

pillow

24

TO PRESERVE THE QUALITY OF YOUR WATCH

Troubleshooting

Troubles

Possible Causes

Solutions

The watch stops

operating.

The mainspring has not been wound.

Wind the mainspring or swing the watch

for a few times so that the watch will start

operating.

If this action does not correct the condition,

consult the retailer from whom the watch

was purchased.

The watch

temporarily loses/

gains time.

The watch has been left in extremely high

or low temperatures for a long time.

Normal accuracy will resume when the

watch returns to normal temperature.

The watch was brought into close contact

with a magnetic object.

Accuracy cannot be recovered. Restoring

the original accuracy requires

demagnetization (repair). Consult the

retailer from whom the watch was

purchased.

The watch was dropped, worn while

playing active sports, hit against hard

surfaces, or exposed to strong vibrations.

Accuracy cannot be recovered. Consult

the retailer from whom the watch was

purchased.

Inspection, adjustment, and overhaul

cleaning have not been performed for the

watch for more than 3 years.

Consult the retailer from whom the watch

was purchased.

The date changes

during daytime.

A.m./P.m. is not correctly set.

Advance the hour hand for 12 hours and

reset the time and date.

Blur in the display

persists.

Small amount of water has got inside the

watch due to deterioration of the gasket,

etc.

Consult the retailer from whom the watch

was purchased.

 * For the solution of troubles other than above, contact the retailer from whom the watch was

purchased.

25

TO PRESERVE THE QUALITY OF YOUR WATCH

English

Содержание 9SA5

Страница 1: ...Printed in Japan BSJ9SCD 2004...

Страница 2: ...ake the service If your watch has a protective film for preventing scratches make sure to peel it off before using the watch If the watch is used with the film on it dirt sweat dust or moisture may be...

Страница 3: ...ically Some loss or gain may occur while the watch is worn However this will be too small to notice in your daily life If a quartz watch resembles an airplane a mechanical watch is like a bicycle All...

Страница 4: ...mechanical watch Characteristics of a mechanical watch For lifelong use of your mechanical watch rule No 1 Wind the mainspring of your mechanical watch at a fixed time As there are rules for everythi...

Страница 5: ...watch rule No 5 Do not give your mechanical watch a strong shock When you play golf tennis or baseball Whenyouplayasportthatgivesyourarmastrong impact Please take off your mechanical watch There are r...

Страница 6: ...ntioned on CERTIFICATE OF GUARANTEE or our website Keep the watch and accessories out of the reach of babies and children Care should be taken to prevent a baby or a child accidentally swallowing the...

Страница 7: ...S WATCH 600m FOR SATURATION DIVING or He GAS DIVER S 600m The watch can be worn for diving using helium gas and can withstand water pressure to a depth of 600 meters The watch is suitable for saturati...

Страница 8: ...he crown Turn the crown from time to time P 22 Screw down crown The screw down crown features a mechanism that can securely lock the crown when it is not being operated in order to prevent any operati...

Страница 9: ...s gear train mechanism for setting the time of the mechanical watch correctly the hands should be set back once slightly and then set forward to the correct time How to set the time and date This watc...

Страница 10: ...guarantee period After that period such adjustments will be chargeable Equally the adjustment will be chargeable if the watch has been subject to any of the conditions below The watch has been used i...

Страница 11: ...nt and position orientation of a watch Accordingly the actual normal usage accuracy when the watch is used by a customer may differ from the numerical value of each item specified in the Grand Seiko S...

Страница 12: ...y GRAND SEIKO GENUINE PARTS When asking for inspection and adjustment by disassembly and cleaning overhaul make sure that the gasket and push pin are also replaced with new ones When your watch is ins...

Страница 13: ...tic wrap etc Wipe off the remaining moisture with a soft cloth Because some titanium bracelets use pins made of stainless steel which has outstanding strength rust may form in the stainless steel part...

Страница 14: ...th pillow 24 TO PRESERVE THE QUALITY OF YOUR WATCH Troubleshooting Troubles Possible Causes Solutions The watch stops operating The mainspring has not been wound Wind the mainspring or swing the watch...

Страница 15: ...aily rate A mean value of daily rates in a condition where the movement before assembly in a case are measured in 6 positions in a fixed manner under artificially controlled environment for 17 days Ca...

Отзывы: