113
Propane Systems
• If you do experience a
propane
freeze up,
close the
main valve and wait at least fifteen (15) minutes before
trying again.
For more information, refer to the regulator
manufacturer’s operator manual
.
• Listen carefully. A
hissing
sound longer than one second,
may indicate a propane leak. If you suspect that there is
a leak, close the shut-off valve,
then
contact your dealer
or qualified propane technician for repair assistance.
• Replace all protective covers and caps on the propane
system after filling. Make sure the valve is closed. Install
the LP bottle cover and use the bungee cord at the bottom
to secure it in place for travel or storage purposes.
Propane Regulator
The two-stage regulator has the only moving component in
the propane system. Its sole function is to reduce the pres-
sure from the propane containers to a safe and consistent low
operating pressure.
The first stage reduces the container pressure to 10-13 lbs.
The second stage further reduces the 10-13 lbs. of pressure
to an operating pressure of 11” W.C. (water column) or 6.35 oz.
of outlet pressure to your appliances.
For optimum performance, the second stage will need to be
adjusted by your dealer (or qualified propane service technician)
using a properly calibrated manometer.
• If the pressure is
too high
, the safety and performance
of the propane system will be affected.
• If the pressure is
too low
, the LP appliances
will NOT operate correctly.
If your RV is equipped with the
automatic
two-stage regulator,
with both cylinders full of propane, turn the lever on the regulator
towards the cylinder you wish to use first. This will now be the
supply
cylinder and the other the
reserve
.
Slowly open both cylinder valves. When the
supply
cylinder is
empty, the indicator will change to red. Now turn the regulator
lever to the
reserve
cylinder side. You may now remove the
empty cylinder to have it refilled without interrupting the flow
from the full bottle. After filling the cylinder, connect the pigtail
hose and slowly open the bottle valve.
Automatic Change Over
Propane Regulator
All propane connections
should be checked periodic-
ally as vibrations from travel
may cause them to loosen.
Failure to check connections
could lead to a propane leak
resulting in a fire or explosion
that could cause serious
injury or death
Propane regulators must
always be installed with
the regulator vent facing
downward. Regulators
that are not located in
baggage compartments
have been equipped with
a protective cover.
Make sure the regulator
vent faces downward and
(if applicable) the cover is
in place to minimize vent
blockage that could result
in excessive gas pressure
causing fire or explosion.
WARNING
WARNING
Содержание Imagine 2021
Страница 1: ......
Страница 2: ......
Страница 4: ...This page is intentionally blank ...
Страница 6: ...This page is intentionally blank ...
Страница 31: ...25 This page is intentionally blank ...
Страница 34: ...28 This page is intentionally blank ...
Страница 72: ...Section Title 66 ...
Страница 84: ...78 This page is intentionally blank ...
Страница 94: ...88 This page is intentionally blank ...
Страница 128: ...122 This page is intentionally blank ...
Страница 148: ...142 This page is intentionally blank ...
Страница 186: ...178 Customer Notes ...
Страница 187: ...179 Customer Notes ...
Страница 188: ...180 Maintenance Record Date Work Performed Next Service Maintenance Record ...
Страница 189: ......