103
Plumbing Systems
Winterization Valve
Winterizing:
1. TURN the
Winterization Valve
to the OPEN position.
2. LOCATE the
Suction Line
& REMOVE the cap
.
• PLACE
Suction Line
into your container of RV antifreeze.
3. TURN ON the
Water Pump
.
4. OPEN all faucet fixtures to circulate RV antifreeze through all waterlines.
(
Kitchen, Lavatory, Shower & Outside Spray Port
)
Normal / Sanitizing:
1. TURN the
Winterization Valve
to the CLOSED position.
2. POUR the Chlorine / Water mixture into
the
Fresh Water Gravity Fill Inlet
.
3. TURN ON the
Water Pump
.
4. OPEN all faucet fixtures to circulate
Chlorine / Water mixture through all
waterlines.
See
page 100-99,
Winterizing the Plumbing System
Suction Line
Winterization Valve
Winterization Valve
CLOSED Position
OPEN Position
See
,
Sanitizing the Plumbing System