8

 

Grand Canyon Gas Logs |3515 E. Atlanta Ave. Phoenix, AZ 85040 

 

LOG PLACEMENT GUIDE 

 
 

 

 

 
 
 
 
 
 
 
 

Содержание JUMBOAWO24LOGS

Страница 1: ...r s instructions If you cannot reach the gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Grand Canyon Gas Log sets are to be installed only in a solid fuel burning fireplace with working flue and construction of noncombustible material The installation including provisions for combustion and ventilation ai...

Страница 2: ... Weathered Oak Log set 238 0 JUMBOSLIMAWO48LOGS 48 Jumbo Slimline Arizona Weathered Oak Log set 271 0 JUMBOSLIMAWO60LOGS 60 Jumbo Slimline Arizona Weathered Oak Log set 309 0 JUMBOBRNR 36 SS 36 Jumbo Stainless Steel Burner 75 00 150K NG 145K LP JUMBOBRNR 42 SS 42 Jumbo Stainless Steel Burner 90 00 165K NG 160K LP JUMBOBRNR 48 SS 48 Jumbo Stainless Steel Burner 110 00 195K NG 190K LP JUMBOBRNR 60 S...

Страница 3: ...g based on chimney height and the appliance Btu rating 6 A fireplace screen must be in place when the appliance is operating and unless other provisions for combustion air are provided the screen shall have an opening s for introduction of combustion air With use of glass doors doors must be open while the appliance is burning to assure proper ventilation 7 The minimum inlet supply pressure for th...

Страница 4: ...4 Grand Canyon Gas Logs 3515 E Atlanta Ave Phoenix AZ 85040 MINIMUM CHIMNEY HEIGHT AND FLUE OPENING ...

Страница 5: ... 1 Remove Merchant Coupling 90 Elbow from the gas inlet side of the burner 2 Drill Out the brass orifice air mixer to the burner and LP orifice size listed below 3 Using piping dope compound replace the orifice air mixer and fitting cap back on the burner Size WC Pressure Minimum BTU Rating Orifice Size 24 11 70K 38 30 11 105K 31 36 11 145K 27 42 11 160K 24 48 11 190K 19 60 11 225K 15 18 21 10 1 2...

Страница 6: ... right side of the burner set up burners according to where the gas enters the fireplace 1 Position the burner in the center of the fireplace with or without a valve system 2 Connect whistle free flex to the burner valve the gas inlet BURNER MEDIA INSTALLATION NG Tear or Rip embers in pieces as small as possible Use either a comb or brush to achieve this The smaller the piece the better the ember ...

Страница 7: ...on Gas Logs 3515 E Atlanta Ave Phoenix AZ 85040 HIGH CAPACITY SAFETY PILOT HCSPK LP NG HIGH CAPACITY MILLIVOLT HCMVQMKLP NG w GCRK EIS EIS OUTDOOR EIS LP w GCRK EIS OUTDOOR LP w GCRK VALVES PARTS LIST IF PURCHASED ...

Страница 8: ...8 Grand Canyon Gas Logs 3515 E Atlanta Ave Phoenix AZ 85040 LOG PLACEMENT GUIDE ...

Страница 9: ...or pick up from the dealer at which the burner was originally purchased Stainless Steel Burners installed outside carry a lifetime warranty against manufacturer defects or breakage This warranty is limited to original purchaser only Electrical and Valves Grand Canyon Gas Logs valves pilot assemblies and electrical components carry a 2 year warranty against breakage or defects from date of purchase...