13
USE AND CARE INSTRUCTIONS
NOTE about LP Gas Tank Exchange Programs
Ÿ
How to Leak Test your LP Gas Tank
For your safety:
LP Gas Model only:
Secure two 20lb LP Gas Tanks to Gas Grill
CAUTION:
When the appliance is not in use the gas
must be turned off at the tanks.
Cylinders Installation Code
The handling, storage, and transporation of all sizes of gas
cylinders must be in accordance with
ANSI/NFPA 58,
Storage and Handling of liquid Petroleum Gases,
or the
CSA
B149.1, Natural Gas and Propane Installation Code.
Turn your LP Gas Tank Valves clockwise to
the closed or OFF positon.
Hang your gas tanks on the top Tank Hooks.
The ring foot of the gas tanks will rest on the
Tank Holder.
Many retailers that sell grills offer you the option of
replacing your empty LP Gas tank through an exchange
service. Use only those reputable exchange companies
that inspect, precision fill, test and certify their tanks.
Exchange your tank only for an OPD safety feature-
equipped tank as described in the LP Gas tank section
of this manual.
Always keep new and exchanged LP Gas tanks in an
upright position during use, transit or storage.
Leak test new and exchange LP Gas tanks BEFORE
connecting one to your grill.
Ÿ
Ÿ
All leak tests must be repeated each time your LP Gas
tank is exchanged of refilled.
When checking for gas leaks do not smoke.
Do not use an open flame to check for gas leaks.
Your grill must be leak tested outdoors in a well-
ventilated area, away from ignition sources such as
gas fired or electrical appliances. During the leak test,
keep your grill away from open flames or sparks.
Do not use household cleaning agents. Damage to
gas assembly components can result.
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
If growing bubbles appear do not use or move
the LP Gas tank. Contact an LP Gas Supplier
or your fire department!
WARNING
!
!
Before usin g th is g as app lian ce read all
instruction s and p erform all gas leak-c heck
p ro cedu res
even
if
th e
prod uc t
was
pre-assembled by the retailer or manufacturer.
WARNING
!
!
Use a clean paintbrush and a 50/50 mild soap and
water solution.
Brush soapy solution onto LP Gas tank in the areas
indicated by the arrows. See diagram.
If growing bubbles appear do not use or move the
LP Gas tank. Call an LP Gas Supplier or your Fire
Department.
Turn all Burner Valves to the OFF position.
Inspect the valve connection port and regulator
assembly for damage or debris. Remove any
debris. Never use damaged or plugged equip-
ment.
Connect the regulator assembly to the tank
valve and HAND TIGHTEN nut clockwise to a
full stop. DO NOT use a wrench to tighten
because it could damage the Quick Coupling
Nut and result in a hazardous condition.
Open the tank valve fully (counterclockwise) and
use a soapy water solution to check all
connections for leaks before attempting to light
"Checking for LP Gas Leaks"
.
If a leak is found, turn the tank valve off and
do not use your grill until the leak is repaired.
LP Gas Model only:
Connect Regulator with Hose to your LPG Tanks
your grill. See
Type 1 connection per
ANSI Z21.58b-2002
Quick
Coupling Nut