1
K3X / K3iX / K3iX P
Страница 1: ...1 K3X K3iX K3iX P...
Страница 2: ...2...
Страница 3: ...FIGURATION OPTIONS MENU 20 8 AUTO OFF OPTION 23 9 BACKLIGHTING THE DISPLAY 23 10 SOUND WHEN PRESSING A KEY 24 11 TARE OPTIONS 24 12 DATA OUTPUT 25 12 1 PR4 Q2 printer 26 12 2 USB USBFR 26 12 3 Frame f...
Страница 4: ...4...
Страница 5: ...re digit is added to the weight value for 4 seconds High Low limits activates deactivates the checkweigher mode Clicking twice will access the H L mode settings Zero button Sets the scale to zero Tare...
Страница 6: ...ings mode it confirms the selection modification made Clock and Up Arrow In weighing mode press to show the totalization amount When keep pressed for 2 seconds will show the date and time In menu mode...
Страница 7: ...ivision Reading in high resolution mode It shows a division 10 times smaller than the one defined in the weighing scale range Double range mode when using the scale range 1 Double range mode when usin...
Страница 8: ...ated for additional options 3 RS 232 data output 4 Connector for the XTREM platform Attach the AC DC power source to the unit and to a mains power outlet for charging the battery before its first use...
Страница 9: ...velled Before using the scale check the bubble level mounted on the platform structure and adjust the levelling feet if necessary Both Xtrem module and the weight sensors mounted on the platform are s...
Страница 10: ...device will be switched off when the key is released 4 INITIAL ZERO SETTING When switching on the unit it will automatically set to zero This will be indicated in the display with the message Automat...
Страница 11: ...ay by following next steps Press to enter the menu settings Press button until the display shows the option then press The following information will be shown K3X terminal embedded software version V...
Страница 12: ...ncing factor such as an air current or the vibration of a nearby engine that may be producing significant disruption To find out the weight of any object within the scale s maximum range place it on t...
Страница 13: ...ndication on the display stays constant non flashing When the scale is emptied the display shows the tare value with a negative sign To cancel the tare press on the tare button again after unloading t...
Страница 14: ...he display returns to weight display mode To change the value associated with a tare value follow the procedure below 1 Use the y keys to select the tare value you wish to modify and press the key 2 T...
Страница 15: ...ption of the configuration menu Pressing on the zero key also deactivates the tare if it happens to be activated The zeroing of the scale is limited to 4 of its maximum capacity Pressing the zero sett...
Страница 16: ...and the upper limit The colour of the display s backlighting changes to red when the weight is outside the interval defined by the upper and lower limit and changes to green when the weight is within...
Страница 17: ...set point established for fine flow contact K3 is opened and contact K2 is closed to indicate that the dosing cycle has finished The light of the LCD display changes to green to indicate that the dosi...
Страница 18: ...press on this key will print a ticket with the following information date and time the Xtrem scale identification the ticket s serial number gross weight tare and net weight just the weight when not u...
Страница 19: ...irst object to be added to the total and double press the print key The weight is printed and added to the accumulated total Repeat this operation to aggregate and print each one of the subsequent wei...
Страница 20: ...e weighing mode Moves to the next menu option in the left direction or changes between the different setting values available Moves to the next level of the options menu or shows the current value of...
Страница 21: ...l separator Scale unit Maximum capacity Max1 when 2 ranges or 2 intervals Scale interval e1 Decimal position Activate double range or double interval mode Max2 when 2 ranges intervals e2 when double r...
Страница 22: ...High limit Checkweigher H L mode on off Dosing mode Speed 1 set point value Dosing mode Speed 2 set point value Dosing mode Set mode fill in or emptying Dosing mode ON OFF Select tare memory Record n...
Страница 23: ...y after 1 hour of inactivity The device switches off automatically after 1 30 hours of inactivity 9 BACKLIGHTING THE DISPLAY This option controls the performance of the LCD display backlight Together...
Страница 24: ...setting for this option is On 11 TARE OPTIONS The possible options are Pre set tare The tare will be kept until the tare key is pressed again with an empty load receptor platform It is the default op...
Страница 25: ...rable Mode in which the data transmission will be made When pressing the print key Continuously at a rate of 5 frames sent per second Automatically every time there is a new stable weight on the scale...
Страница 26: ...ontent is programmable by the user The options for configuring this document are in the section of the main menu 12 2 USB USBFR Format compatible with the GRAM USB adapter for PC type computer with Mi...
Страница 27: ...cluding the decimal point 10 11 Measurement unit g kg oz lb 12 Carriage return 13 End of text The status byte is built from the binary values of the display indications tare zero gross net and stabili...
Страница 28: ...h i 69h 20h 49h Bit 7 Bit 6 stable Bit 5 Bit 4 Bit 3 zero Bit 2 Bit 1 Tare off Bit 0 Gross 0 1 0 0 1 0 0 1 The status byte is 62h b 62h 20h 42h Bit 7 Bit 6 stable Bit 5 Bit 4 Bit 3 no zero Bit 2 Bit 1...
Страница 29: ...6Ah 20h 4Ah Bit 7 Bit 6 stable Bit 5 Bit 4 Bit 3 zero Bit 2 Bit 1 Tare on Bit 0 Net 0 1 0 0 1 0 1 0 The status byte is 6Bh k 6Ah 20h 4Ah Bit 7 Bit 6 stable Bit 5 Bit 4 Bit 3 zero Bit 2 Bit 1 Tare on...
Страница 30: ...each print whether it is a single ticket or a ticket with accumulated total Automatic paper cutting ON OFF This function is only possible with ESC Pos printers equipped with paper cutting device Decim...
Страница 31: ...message when trying to modify them The Xtrem unit records the date and time of the last modification in any of these parameters Modifying these parameters may imply the loss of the equipment warranty...
Страница 32: ...iguration settings for the automatic zero setting of the scale after power on and the scale zero tracking device Activate deactivate the initial zero setting feature When select the indication is auto...
Страница 33: ...value Manual input of the span slope 5 digits The divisor needed to transform A D converter counts to the measurement unit Prints a ticket with the configuration and calibration settings in the device...
Страница 34: ...ch you have to choose from the attached table Use the and keys to change the value and validate by pressing on the key 7 Lastly the message will briefly appear indicating that the calibration has been...
Страница 35: ...13 13 12 12 11 11 10 40 05 41 12 16 15 15 14 14 13 13 12 12 11 11 41 12 42 19 16 16 15 15 14 14 13 13 12 12 11 42 19 43 26 17 16 16 15 15 14 14 13 13 12 12 43 26 44 32 17 17 16 16 15 15 14 14 13 13 1...
Страница 36: ...use oscillations in the weight indication by exerting a variable force on the load cells When sets to ON the indicator doesn t show intermediate weight values when loading unloading the scale The resu...
Страница 37: ...ration mode for controlling the optional relay board The relay outputs will be controlled by the H L operation mode The K1 relay closes when the weight on the scale is greater than the limit The K2 re...
Страница 38: ...38 Setting of values for dosing operation Weight set point for speed 1 Weight set point for speed 2 Type of dosing Loading or unloading Yes No Activating the dosage mode when switching on the unit...
Страница 39: ...z y 85 dB Real time clock RTC Date and time hours minutes seconds Battery backup using a CR2032 3V Serial RS232C output K3X and K3iX models RS232 port not available in K3iXP model Transmission only RS...
Страница 40: ...e mm K3X 220 x 180 x 83 mm K3iX 225 x 195 x 111 mm K3iXP 225 x 195 x 121 mm Weight including battery K3X 1 7 kg K3iX 2 5 kg K3iXP 2 8 kg Assembly Desktop Optional Swivel mount wall column Tightness IP...
Страница 41: ...MULTI PIN MOBILE MALE P700 5 PINES 18 CONNECTIONS RS 232 serial output NOTE Not present in K3iXP model XTREM scale connector PIN No SIGNAL PIN 4 RxD PIN 5 TxD PIN 6 GND PIN No SIGNAL PIN 1 Vcc PIN 2 T...
Страница 42: ...tion seal to open the XTREM cover set to unlock the sealing switch The instrument must be adjusted and verified calibrated again Calibration weight Max Adjust weight should be Max The division should...
Страница 43: ..._________ _______________________________________________________________ _______________________________________________________________ ______________________________________________________________...
Страница 44: ...44...