16
English
Installation
To ensure reliable operation, make sure the following is observed:
The cabinet must be located in a dry and ventilated room.
The cabinet is designed to operate in ambient temperatures b16°C and +35°C.
Avoid location in direct sunlight or near any heat sources, i.e. an oven.
The cabinet can be installed freestanding against a wall or Compact 210 can be built
under a worktop.
The cabinet must have sufficient ventilation and free air circulation beneath, above and
behind the cabinet. There must be a minimum clearance of 30 mm above the cabinet.
For versions with legs, use the screws on the legs to make sure that the cabinet stands
level and upright.
If the cabinet has been transported in horizontal position, it must stand upright af least 2
hours before it is started to allow the oil from the compressor to run back.
The cabinet must not be located in a chloride/acid-containing environment (swimming-bath
etc.) due to risk of corrosion.
Gram-webshop.nl
Gram-webshop.nl