background image

15.

PROFILE OPTIONS SCREEN

If a profile is already running and you go to the Menu, there will be an option for Profile Options. This will 
allow you to cancel the profile, extend the current step time, or manually proceed to the next step.

 •  If you select Brew, the controller will set the profile step 1 temperature and start the timer. If auto 

proceed is set to YES, once the timer is finished the controller will change the temperature to the next 
step and start the timer for the next step until all steps are complete. If the global auto proceed is set to 
NO, the controller will display the interaction screen when timer finishes and wait for user to manually 
proceed to the next step.

•  If you select Edit, you will navigate through each step which will allow you to change the step values.

Содержание Conical Fermenter

Страница 1: ...Instructions Conical Fermenter...

Страница 2: ...ANATOMY SCHEMATICS P 2 FERMENTING WITH THE STANDARD FERMENTER P 5 COLLECTING AND TRANSFERRING P 8 CONTROLLED HEATING AND COOLING P 11 PRODUCT NAME CONICAL FERMENTER Rated 12V 2 75A max Power Adapter...

Страница 3: ...and Wall Plug 2 m 6 5 ft M12 3pin power cord Fermenter Body Digital Temperature CONTROLLER Fermenter lid Rubber Bung AIRLOCK 01 5 cm 2 Tri Clamp Cone Plug seal LIQUID INLET DUAL VALVE TAP Silicon Tra...

Страница 4: ...ket 10 Digital temperature controller replace digital display with this controller 11 Ferrule cone connection 12 Fermenter base 13 Dual valve tap 14 Cooling connection coupler 15 Fermenter power cord...

Страница 5: ...14 15 16 17 18 19 20 22 23 21 glycol chiller fig 1...

Страница 6: ...ries Fermentation is arguably the most important part of producing a good quality beer A good fermentation environment has a consistent controlled temperature base exposure to oxygen is minimised and...

Страница 7: ...th a damaged cord or plug or if the appliance malfunctions or has been damaged in any manner Return appliance to your nearest retail service provider for examination repair or adjustment 7 The use of...

Страница 8: ...m of the fermenter by inserting the ferrule seal then using the tri clamp to tighten it See page 9 for more information Plug the 2 m 6 6 ft power cord into the back of the fermenter Plug the other end...

Страница 9: ...r Make sure to scrub all surfaces Empty the water and rinse the fermenter with fresh clean water Then use the Mangrove Jack s No Rinse Sanitiser Attach the digital temperature controller by clipping i...

Страница 10: ...the sediment is removed on a regular basis of 2 3 days This part opens and closes with a spring loaded lever on the side of the valve to ensure minimal beer wastage Collecting Transferring Ball valve...

Страница 11: ...ample of yeast that you dumped after fermentation has finished The beer valve can be used at any point during fermentation to collect samples to test the gravity of the beer To do this open the ball v...

Страница 12: ......

Страница 13: ...irect applied heat in cold temperatures which is much better for the yeast 3 It provides far superior insulation that cannot be achieved by a standard insulation jacket In the cavity of the fermenter...

Страница 14: ...rmenter body Set your temperature and schedule eg heat the temperature to 18 C 64 4 F and keep it there for 3 days For setting a schedule and other options on the controller see below MAIN DEFAULT SCR...

Страница 15: ...lable Metric Imperial Hysteresis margin of temperature variation allowed before the temperature control turns back on 0 1 2 0 C 32 2 35 6 F adjustment Mode Heat Cool default Heat Only Cool Only Off Au...

Страница 16: ...s you to edit the time and temperature of each step and has auto proceed option for steps 1 3 3 Custom 1 you can specify amount of steps up to 5 edit all values as above 4 Custom 2 same as custom 1 An...

Страница 17: ...tep 1 temperature and start the timer If auto proceed is set to YES once the timer is finished the controller will change the temperature to the next step and start the timer for the next step until a...

Страница 18: ...Ambient temp 21 C 64 F Volume 23L Time hours 0 1 2 3 4 5 6 7 8 9 10 11 12 Temperature 18 C 19 2 C 20 1 C 21 C 22 2 C 22 9 C 24 1 C 25 C 26 2 C 27 3 C 28 1 C 29 1 C 30 4 C 64 F 66 5 F 68 1 F 69 8 F 71...

Страница 19: ...ontact with the wort beer and is never seen by you it is not something that needs to be cleaned or sanitised meaning your beer is never compromised With the Glycol Chiller you are operating your syste...

Страница 20: ...www grainfather com Reorder 72663 Version 2...