ADC-24 User Guide
Page 11
•
Switch
6
and
7
defines the
Category Code.
Function
SW6
SW7
General 0
0
Digital Converter
1
0
Laser, CD
0
1
Magnetic Tape
1
1
•
Switch
8
determines the
Generation Table
.
Function
SW8
1
st
Generation or Higher
0
Original 1
ADC-24 Troubleshooting
The table below lists several ADC-24 problems, and provides a variety of “checklist” procedures
designed to solve them.
Problem
Procedure
No signal at either
AES output.
•
Is power applied? Check power LED and power supply.
No audio on AES
output.
•
Is input connected correctly? Check
+
to pin 2, or ground to pin 3.
Front panel meters
not registering.
•
Adjust input levels.
Ext Ref indicator not
lit on front panel.
•
Is AES reference connected? Check that an AES signal is applied to
the reference input if you want synchronized sampling.
•
Is the reference input a valid AES signal?
•
Is the reference input sampling frequency between 30 KHz and 50
KHz?
NOTE
Please contact the GPS factory if the problem still exists after completing the
above procedures.