Graham-Patten D/ESAM 820 Скачать руководство пользователя страница 6

Error! Main Document Only.-6 

 Alignment

D/ESAM 820 User’s Guide

Audio Output Module

The Audio Output Module drives a total of 14 balanced signals:

4 analog Program outputs

4 analog Monitor outputs

4 analog Meter outputs

2 AES digital Program outputs (each output has two discrete channels)

Each analog output reference level can be adjusted from -8dBu to +10dBu using a
gain trimmer.  Use the illustration below for the following adjustment procedures.

1

2

3

2

3

AUDIO OUTPUT MODULE
04-0130-

4

4

3

3

2

2

1

1

4

3

2

1

PROGRAM

METER

MONITOR

R511

R510

R611

R610

-5

GND +5

+15

-15

Program Output
Gain Trims

Meter Output
Gain Trims

Monitor Output
Gain Trims

Analog Output Card, Gain Trim Locations

NOTE

The -03 version of the module can also be used for the D/ESAM 800.  Jumper

J480 

is used for configuration:

Data mode 1 configures the module for the D/ESAM 820.

Data mode 0 configures the module for the D/ESAM 800.

Refer to the silk screen on the module itself for jumper 

J480 

positions and data

mode indications.

Содержание D/ESAM 820

Страница 1: ...hem to their uppermost limit 6 dB position Leave each fader there 3 To align faders press LOCK UNLK hold it down and press FADER SPLIT Electrical position now matches the physical scale printed on the...

Страница 2: ...operating level of 10dBu to 14dBU Operating levels are changed by replacing resistor networks socketed which are available from GPS Use the table below to select the appropriate resistor network Anal...

Страница 3: ...be tested 3 Select R in the Preview Section on the Control Panel and assign virtual machine which contains the inputs to be aligned to R Refer to the Machine Assignment section in Chapter 3 for machi...

Страница 4: ...CONTROL ADDRESS BLOCK AUDIO ADDRESS BLOCK SYNC ASYNC 110 250 SYNC ASYNC 110 250 SYNC ASYNC 110 250 SYNC ASYNC 1J1 1J3 2J1 2J3 3J1 3J3 4J1 4J3 e AES Input Module Assy 04 0164 00 The Digital AES Input...

Страница 5: ...SAM 820 Series module definition 04 0167 XX is compatible with any of the previous versions of the digital input modules 04 0148 00 or 04 0141 00 Jumper Settings The module has two sets of jumpers for...

Страница 6: ...on below for the following adjustment procedures 1 2 3 2 3 AUDIO OUTPUT MODULE 04 0130 4 4 3 3 2 2 1 1 4 3 2 1 PROGRAM METER MONITOR R511 R510 R611 R610 5 GND 5 15 15 Program Output Gain Trims Meter O...

Страница 7: ...ccidental adjustments NOTE The internal tone generator can be used for alignment In Chapter 5 see the Alignment Menu 6 1 section for setting tone generator options Program Output Adjustments The follo...

Страница 8: ...d MIX OUT Ensure that PGM is selected in the Program Preset section 3 Bring up the fader s so that meters read 0VU 8PPM 4 Ensure that MONO 2 CH and LEVEL BAL indicators are OFF In addition ensure that...