Graham-Patten D/ESAM 820 Скачать руководство пользователя страница 5

D/ESAM 820 User’s Guide

Alignment 

 Error! Main Document Only.-5

The module has four LED’s (one for each input pair) that flash when errors occur.
Occasional errors are concealed by the AES input module.  Excessive errors are
indicated by the LED ON continuously.  Under this condition, the associated input
pair will mute.

The Digital AES Input Module is available in three styles:

04-0164-01 — Standard eight channels (4 AES inputs) with no sample
rate converters.

04-0164-02 — Four of the eight channels (1 - 4) are sample rate
converted.

04-0164-00 — All eight channels are sample rate converted.

Installation

When setting the D/ESAM 820 Series module definition, 04-0167-XX is compatible
with any of the previous versions of the digital input modules (04-0148-00 or
04-0141-00).

Jumper Settings

The module has two sets of jumpers for each input.

The termination jumper allows for either 250

 or 110

.  The standard

setting is 110

.

Synchronization jumpers are for the sample rate converted inputs.
When the jumper is set to 

ASYNC

, the AES input will be sample rate

converted.  When the jumper is set to 

SYNC

, the AES input will bypass

the sample rate converter.

The default setting for the sample rate converted input is 

ASYNC

 and

all 48kHz synchronized inputs are set to 

SYNC

.

The following table shows the jumpers for each AES input.

AES Input Jumpers (Assy. #04-0164-00)

Inputs

Termination

Synchronization

1 & 2

1J1

1J3

3 & 4

2J1

2J3

5 & 6

3J1

3J3

7 & 8

4J1

4J3

Содержание D/ESAM 820

Страница 1: ...hem to their uppermost limit 6 dB position Leave each fader there 3 To align faders press LOCK UNLK hold it down and press FADER SPLIT Electrical position now matches the physical scale printed on the...

Страница 2: ...operating level of 10dBu to 14dBU Operating levels are changed by replacing resistor networks socketed which are available from GPS Use the table below to select the appropriate resistor network Anal...

Страница 3: ...be tested 3 Select R in the Preview Section on the Control Panel and assign virtual machine which contains the inputs to be aligned to R Refer to the Machine Assignment section in Chapter 3 for machi...

Страница 4: ...CONTROL ADDRESS BLOCK AUDIO ADDRESS BLOCK SYNC ASYNC 110 250 SYNC ASYNC 110 250 SYNC ASYNC 110 250 SYNC ASYNC 1J1 1J3 2J1 2J3 3J1 3J3 4J1 4J3 e AES Input Module Assy 04 0164 00 The Digital AES Input...

Страница 5: ...SAM 820 Series module definition 04 0167 XX is compatible with any of the previous versions of the digital input modules 04 0148 00 or 04 0141 00 Jumper Settings The module has two sets of jumpers for...

Страница 6: ...on below for the following adjustment procedures 1 2 3 2 3 AUDIO OUTPUT MODULE 04 0130 4 4 3 3 2 2 1 1 4 3 2 1 PROGRAM METER MONITOR R511 R510 R611 R610 5 GND 5 15 15 Program Output Gain Trims Meter O...

Страница 7: ...ccidental adjustments NOTE The internal tone generator can be used for alignment In Chapter 5 see the Alignment Menu 6 1 section for setting tone generator options Program Output Adjustments The follo...

Страница 8: ...d MIX OUT Ensure that PGM is selected in the Program Preset section 3 Bring up the fader s so that meters read 0VU 8PPM 4 Ensure that MONO 2 CH and LEVEL BAL indicators are OFF In addition ensure that...