10  LIMITED WARRANTY

GF Health Products Inc.

 warrants this product to be free from manufacturing defects in material and 

workmanship for its period of warranty that is in accordance with industry standards. This warranty 
is extended only to the original purchaser/consumer or dealer/non-consumer of this new product 
and to no other purchaser or transferee.

GF Health Products, Inc.

 warrants the Lumex

®

 LF1031FP Hydraulic Patient Lift and its components to 

be free from defects in workmanship and materials as listed below:

Frame / Parts: 1 Year 
Hydraulic Pump: 1 Year

The Warranty period for the consumer commences on the irst date a product is delivered to consumer 
by seller/dealer. If the product is rented or leased, the warranty period commences on the invoice 
date from 

GF Health Products, Inc. 

A copy of the invoice showing date of purchase must be provided 

when submitting warranty claims. When proof of purchase date is not provided, warranty coverage 
shall commence upon 

GF Health Products, Inc.’s

 invoice date to the dealer/purchaser.

If within the warranty period, the product or component part is proven to 

GF Health Products, Inc.’s

satisfaction to be defective, 

GF Health Products, Inc.

 shall provide, at its option, one of the following: 

(1) repair or replacement of any defective or nonconforming part or product or (2) a credit and/
or refund of the original selling price. GF HEALTH PRODUCTS, INC.’S SOLE OBLIGATION AND YOUR 
EXCLUSIVE REMEDY UNDER THIS WARRANTY SHALL BE LIMITED TO SUCH REPAIR, REPLACEMENT, 
CREDIT AND/OR REFUND. This warranty does not include any labor charges incurred in replacement 
part(s) installation or any associated freight or shipping charges to the manufacturer.

For warranty service, please contact the authorized distributor from whom you acquired your 

GF 

Health Products, Inc.

 product. Upon receiving notice of an alleged defect in a product, 

GF Health Prod-

ucts, Inc.

 will issue a return authorization. The defective product or part(s) must then be returned, 

at the purchaser’s cost, for warranty inspection using the serial number as identiication (or, if the 
product is not serialized, lot number and date code) within thirty (30) days of return authorization 
issue date. In the event you do not receive satisfactory warranty service, please contact 

GF Health 

Products, Inc.

 at the address below. DO NOT return products to our factory without prior authorization.

LIMITATIONS AND EXCLUSIONS: The foregoing warranty excludes consumables, such as ilters and 
tubing, as these require routine maintenance. The foregoing warranty shall not apply to serial num-
bered products if the serial number has been removed or defaced. Products subjected to negligence, 
abuse, misuse, improper operation, improper maintenance, improper cleaning, improper storage, or 
damages beyond 

GF Health Products, Inc.’s

 control are not covered by this warranty, and that evalua-

tion shall be solely determined by 

GF Health Products, Inc.

 This warranty shall not apply to problems 

arising from normal wear and tear or failure to follow instructions. The warranty shall also not apply 
to products modiied without 

GF Health Products, Inc.’s

 express written consent; nor shall it apply if 

parts not manufactured by 

GF Health Products, Inc.

, or if parts not complying with original equipment 

speciications are added to 

GF Health Products, Inc.

 products, or if the product or part is serviced by 

an entity not authorized by 

GF Health Products, Inc.

THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WAR-
RANTIES AND IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED 
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, AND 
SHALL NOT EXTEND BEYOND THE DURATION OF THE EXPRESS WARRANTY PROVIDED 
HEREIN, AND THE REMEDY FOR VIOLATIONS OF ANY IMPLIED WARRANTY SHALL BE 
LIMITED  TO  THE  REPAIR,  REPLACEMENT,  CREDIT  AND/OR  REFUND  OF  THE  DEFEC-

Содержание Lumex LF1030

Страница 1: ...LF1031FP INS LAB RevA11 2011 GF Health Products Inc Read this manual before operating your Patient Lift Save this manual for future use LF1031FP HYDRAULIC PATIENT LIFT WITH FOOT PEDAL USER MANUAL...

Страница 2: ...SAFETY PRECAUTIONS 4 WARNINGS 4 3 FEATURES 6 4 HANDLING PROCEDURES 7 SHIPPING AND TRANSPORTATION INSTRUCTIONS 7 5 ASSEMBLY INSTRUCTIONS 8 COMPONENTS 8 ASSEMBLY 9 6 OPERATING INSTRUCTIONS 11 LIFTING T...

Страница 3: ...s with proper supervision and with a capable individual acting as patient It is extremely important to know how a patient will feel in the patient lift We suggest that the operator try all the various...

Страница 4: ...the warranty WARNING Unauthorized modiication of your patient lift could cause personal injury property damage and void the warranty WARNING The LF1031FP Hydraulic Patient Lift maximum weight capacit...

Страница 5: ...nd may result in damage to the unit Consult your Lumex Dealer for further information WARNING Use extreme care caution and common sense when utilizing a patient lift Special attention must be given to...

Страница 6: ...suspension hydraulic pump pump knob pump locking and unlocking adjustment handle boom height adjustment mast boom height adjustable locking casters foot pedal base width adjustment base width adjusta...

Страница 7: ...r authorized Lumex Dealer 2 Remove all loose packing from the carton 3 Carefully remove all the components from the carton Info Unless the patient lift is to be used immediately retain boxes container...

Страница 8: ...ents LF1031FP Hydraulic Patient Lift with Foot Pedal 9 2 4 10 3 1 7 6 5 8 Item Qty Description 1 1 Mast Boom Pump assembly 2 1 Base 3 2 L insert 4 2 Push handle 5 1 Spreader bar to boom attachment bol...

Страница 9: ...ted in the same direction as the base legs insert the mast into the sleeve 4 Insert the locking pin through the holes of the sleeve and mast and attach the locking cable to the end of the pin 5 Screw...

Страница 10: ...si tion To elevate turn the pump knob clockwise until hand tight and operate the pump handle 9 Operate the foot pedal to adjust the base width The picture at near right shows the base end op posite th...

Страница 11: ...be free to roll so that the patient lift can stabilize as the patient is lifted from the bed WARNING To ensure stability while lifting or transferring a patient the patient lift legs must be locked in...

Страница 12: ...le maintaining support gently lean the patient forward Place the folded sling behind the patient s back and push it down until it touches the seat of the chair 3 Use the loops to pull the leg sections...

Страница 13: ...e toward attendant pull sling to smooth it and center patient on sling 5 Pull the leg loops forward and under the thighs 6 Cross the loops one through the other 7 With base of lift under bed SLOWLY re...

Страница 14: ...ially hazardous condition could exist BEFORE EACH USE Before each use of the patient lift ensure that All nuts and bolts are tight The lift moves freely with caster brakes off Rear caster brakes opera...

Страница 15: ...ft that are under a great deal of stress for damage and wear These areas include slings spreader bars spreader bar suspension and mounting hardware pump mounting hardware and all pivot points Inspect...

Страница 16: ...right Use two 9 16 wrenches to remove the hardware that secures top of pump to upper boom bracket This will free the pump to rotate downward 3 Remove the bottom of the exist ing pump from the lower m...

Страница 17: ...right Use a hex bolt washers and hex nut to secure pump to mast Use two 9 16 wrenches to tighten 2 Attach the top of the hydraulic pump to the upper boom bracket as shown at right Use a hex bolt washe...

Страница 18: ...ositions X X Ensure that locking knob is in place and operating properly X X Inspect all base hardware for wear X Mast Ensure that mast is fully engaged and locked into mast sleeve X X Inspect mast fo...

Страница 19: ...o up or down Air in the cylinder Bleed the cylinder by turning the release knob and push down on the mast Pump up the lift again and turn the release knob again Loss of hydraulic luid leaking cylinder...

Страница 20: ...ht Clearance 4 5 Base length 51 Lifting height range Info As measured from point where sling attaches to spreader bar Minimum 24 Maximum 75 5 Range 50 3 Mast height 55 1 Weight capacity 400 lb 181 kg...

Страница 21: ...ct Upon receiving notice of an alleged defect in a product GF Health Prod ucts Inc will issue a return authorization The defective product or part s must then be returned at the purchaser s cost for w...

Страница 22: ...f incidental or consequential damage or limitation on how long an implied warranty lasts so the above exclusion and limitations may not apply to you The warranties contained herein contain all the rep...

Страница 23: ...rom the loor 12 Lowering the patient onto a bed 11 Lowering the patient to the loor 12 Lubrication 14 M Maintenance schedule 18 N NOTICE statement signiicance 3 O Operating Instructions 11 R Removing...

Страница 24: ...Made in Taiwan...