6 of 13
4. Assembly
4.1 Tank assembly
First insert the circumferential profile seal
into the
sealing groove in the lower half shell
. Lightly coat
the entire seal with the enclosed soft soap.
Then
insert
the
centering
pins
into
the
corresponding slots around the circumference.
The upper half shell
should now be positioned onto the lower half shell
.
Make sure that the seal
doesn’t slip out of the groove.
To install the quick connectors
,
attach them in an
alternating manner to the left and to the right (counter-
clockwise and clockwise). For this, every second
connector should be adjusted by hand initially, and then
driven securely into place using a hammer and a block
of wood. If attaching the clips is problematic, try
lubricating the inner edges of the connectors and/or
using 3
– 4 C-clamps positioned evenly around the lip
of the tank during the installation. Ensure the
connectors are engaged in their final position. After
completing the installation of the first half of the
connectors, repeat the procedure for the remainder