Batch Dispense or Ratio Check
24
309535L
Batch Dispense or
Ratio Check
Follow this procedure to dispense a batch (into one con-
tainer) or verify a ratio setting (use separate container
for fluid A and B). Dispense into a container with gradua-
tions no greater that 5% of each component.
c.
Press Start
. Pump A light comes on.
5.
Batch dispense: stir material until mixed.
Ratio check: compare A and B fluid dispense.
Batch dispense is always 1 liter of total volume,
regardless of ratio setting.
1.
Turn knob to batch dispense
. Turn off air regula-
tor. Open main air shutoff valve. Adjust air pressure
to 50 psi (0.35 MPa, 3.5 bar).
2.
Dispense fluid A:
a.
Close fluid shutoff valves and sampling valves A
and B.
b.
Place a clean 1 quart (1000 cc) container under
sampling valve A.
I
O
PSI
Bar
MPa
PSI
Bar
MPa
B
A
B
A
0
Close
A
Close
b.
a.
a.
d.
Slowly open and adjust sampling valve A to
achieve desired flow. The pump stops automati-
cally when dispense is complete. Pump A light
turns off, Pump B light comes on.
3.
Close sampling valve A.
4.
Dispense fluid B as follows:
a.
Batch dispense: move the 1 quart (1000 cc)
container under sampling valve B.
Ratio check: place clean 1 quart (1000 cc) con-
tainer under sampling valve B.
b.
Slowly open and adjust sampling valve B to
achieve desired flow. The pump stops automati-
cally when dispense is complete. Pump B light
turns off.
I
O
PSI
Bar
MPa
B
A
c.
Open
A
d.
Close
A
B
A
B
a.
Open
b.
Содержание Xtreme Mix 309535L