Flushing
309535L
15
Using Solvent Siphon Tube
4.
Adjust regulator to desired pressure; use lowest
pressure possible.
5.
Disengage trigger lock and trigger gun into a
grounded pail. Flush out mixed material until clean
solvent dispenses. Engage trigger lock.
6.
Shut off solvent pump and close solvent shutoff
valve.
7.
Follow Pressure Relief Procedure, page 10.
Engage trigger lock.
ti1950a
ti1953a
ti1949a
ti1953a
ti1949a
1.
Press Stop
to turn off pumps. Follow Pressure
Relief Procedure, page 10. Engage trigger lock.
Remove spray tip.
2.
Connect fluid hose with solvent siphone tube to
pump A 3-way ball valve. Put solvent siphon tube
into a grounded solvent pail.
3.
Turn pump A 3-way ball valve to open suction tube
line, as shown below. Arrow on handle shows direc-
tion of flow.
4.
Open main air shutoff valve. Open shutoff valve A.
Close sampling valves A and B.
TI1948A
ti1949a
Suction Tube Line
A
I
O
PSI
Bar
MPa
PSI
Bar
MPa
A
B
Open
Close
Close
Close
Содержание Xtreme Mix 309535L