Troubleshooting
3A0420V
37
Pump Troubleshooting
This chart uses proportioning fluid gauges to determine pump malfunctions. Observe the gauge readings during the
stroke direction indicated by the bold arrow, and immediately after closing the gun or mix manifold. Refer to other
manuals to troubleshoot individual components.
Fluid outlet pressure gauges split
only at the top changeover (if one
gauge drops the other will rise).
Not fully loading one side on
upstroke.
Increase feed pressure on side that
dropped.
Increase feed hose size.
Clean inlet strainer or hopper screen.
Air mixed in fluid from excessive agi-
tation or circulation.
Flush and add new fluid.
Problem
Cause
Solution
TROUBLE AREA:
Resin Pump Leakage
1. Throat packing
2. Piston packing
3. Piston ball check
Resin
Pump
Falling
Rising
Hardener
Pump
Falling
Falling
Rising
Rising
TROUBLE AREA:
Hardener Pump Leakage
1. Throat packing
2. Piston packing
3. Piston ball check
TROUBLE AREA:
Resin Pump Leakage
1. Throat packing
2. Intake ball check
TROUBLE AREA:
Hardener Pump Leakage
1. Throat packing
2. Intake ball check
Resin
Pump
Hardener
Pump
Falling
Rising
Resin
Pump
Hardener
Pump
Resin
Pump
Hardener
Pump
r_258914_3a0420a_11a
r_258914_3a0420a_11a
r_258914_3a0420a_10a
r_258914_3a0420a_10a
Содержание XP-h
Страница 45: ...Repair 3A0420V 45 ...
Страница 48: ...Parts 48 3A0420V Cart Mounted System Continued 31 30 36 35 Quickset Mix Manifold Models TI19233a ...