Test Ground Strip Resistance
Using an ohmmeter, measure the resistance between
the latch housing (206) and the ground lug (214).
The ground strip is grounded through the cart back
to the ground lug. Resistance must be less than 100
ohms. If greater than 100 ohms, replace the ground
strip (240).
Figure 20 Test Ground Strip Resistance
Test Cylinder Resistance
Remove the enclosure door. Using an ohmmeter,
measure the resistance from the pump (209) to the
ground lug (214). Resistance must be less than
100 ohms. If greater than 100 ohms, replace the
grounding cylinder.
Figure 21 Test Cylinder Resistance
3A2497C
39