Warnings 

3A6939B

5

EQUIPMENT MISUSE HAZARD

Misuse can cause death or serious injury.

Do not operate the unit when fatigued or under the influence of drugs or alcohol.

Do not exceed the maximum working pressure or temperature rating of the lowest rated system com-
ponent. See Technical Data in all equipment manuals.

Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all 
equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information 
about your material, request Safety Data Sheet (SDS) from distributor or retailer.

Turn off all equipment and follow the Pressure Relief Procedure when equipment is not in use.

Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manu-
facturer’s replacement parts only.

Do not alter or modify equipment. Alterations or modifications may void agency approvals and create 
safety hazards.

Make sure all equipment is rated and approved for the environment in which you are using it.

Use equipment only for its intended purpose. Call your distributor for information.

Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

Do not kink or over bend hoses or use hoses to pull equipment.

Keep children and animals away from work area.

Comply with all applicable safety regulations.

MOVING PARTS HAZARD

Moving parts can pinch, cut or amputate fingers and other body parts.

Keep clear of moving parts.

Do not operate equipment with protective guards or covers removed.

Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, 
follow the Pressure Relief Procedure and disconnect all power sources.

TOXIC FLUID OR FUMES HAZARD

Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or 
swallowed.

Read Safety Data Sheet (SDS) to know the specific hazards of the fluids you are using.

Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.

BURN HAZARD

Equipment surfaces and fluid that is heated can become very hot during operation. To avoid severe 
burns:

Do not touch hot fluid or equipment.

PERSONAL PROTECTIVE EQUIPMENT

Wear appropriate protective equipment when in the work area to help prevent serious injury, including 
eye injury, hearing loss, inhalation of toxic fumes, and burns. Protective equipment includes but is not 
limited to:

Protective eyewear, and hearing protection. 

Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer.

Содержание Viscount High-Flo Plus 25E932

Страница 1: ...r purging lines with caustics acids abrasive line strippers and other similar fluids For professional use only See Models page 3 for model information See Technical Specifications page 19 for maximum...

Страница 2: ...nce 10 Preventive Maintenance Schedule 10 Troubleshooting 11 Repair 12 Disassembly 12 Reassembly 12 Parts 14 Viscount II Pump Model 25Exxx with Sealed 4 Ball Plus Lower 14 Dimensions 15 Performance Ch...

Страница 3: ...Fittings Style Lower Material Rod Coating Cylinder Coating 25E932 Viscount II 2500cc 17Z387 Sealed tri clamp SST Ultralife Ultralife 25E933 Viscount II 3000cc 17Z388 Sealed tri clamp SST Ultralife Ul...

Страница 4: ...ential static sparking Ground all equipment in the work area See Grounding instructions Never spray or flush solvent at high pressure Keep work area free of debris including solvent rags and gasoline...

Страница 5: ...t surfaces Do not kink or over bend hoses or use hoses to pull equipment Keep children and animals away from work area Comply with all applicable safety regulations MOVING PARTS HAZARD Moving parts ca...

Страница 6: ...J 10 Micron Return Filter K Hydraulic Return Line L Hydraulic Supply Line M Drain Line N Pressure Reducing Valve P Hydraulic Supply Line Pressure Gauge R Return Line Shutoff Valve S Supply Line Shuto...

Страница 7: ...llow local code Object being sprayed follow local code Solvent pails used when flushing follow local code Use only conductive metal pails placed on a grounded surface Do not place the pail on a non co...

Страница 8: ...N which has a drain line M running to the hydraulic return line K controls the hydraulic pressure to the motor Hydraulic Return Line Use a minimum 1 2 in 13 mm ID return line K The motor has a 3 4 in...

Страница 9: ...lockwise increasing pressure until pump starts 5 Cycle pump slowly until all air is pushed out and pump and hoses are fully primed 6 Close the fluid shutoff valve D downstream of the pump The pump sho...

Страница 10: ...ydraulic power supply manufac turer s recommendations on reservoir and filter cleaning and periodic changes of hydraulic fluid Performing a Stall Test Perform a stall test periodically to ensure the p...

Страница 11: ...n packings Replace See lower manual No output Improperly installed ball check valves Check and repair Pump operates erratically Exhausted fluid supply Refill and re prime pump Held open or worn ball c...

Страница 12: ...motor 1 follow these steps a Loosen but do not remove the screws 13 holding the mounting plate 12 to the motor 1 b Screw the tie rods 3 into the mounting plate 12 and torque to 50 55 ft lb 68 75 N m...

Страница 13: ...ten the lock nuts and torque to 50 60 ft lb 68 81 N m 9 Install the shields 9 by engaging the bottom lips with the groove in the top plate Snap the two shields together The top of the shield may be sl...

Страница 14: ...ion Qty 1 223646 MOTOR Viscount II see detailed parts list in manual 308048 1 2 See page 2 LOWER Sealed 4 Ball Plus see detailed parts list in manual 3A5348 1 3 16H434 TIE ROD 10 80 in 274 3 mm 8 37 i...

Страница 15: ...or Lower Size Lower Type A B Approx Weight in mm in mm lb kg 25E932 VISCOUNT II 2500cc Sealed 57 2 1452 30 2 767 205 93 25E933 VISCOUNT II 3000cc Sealed 203 92 25E934 VISCOUNT II 4000cc Sealed 202 92...

Страница 16: ...Dimensions 16 3A6939B Motor Mounting Hole Diagram 6 186 in 157 mm 7 43 in 7 43 in 188 mm 6 186 in 157 mm 4X 3 8 16 UNC 2B Viscount II Motor Mounting Hole Layout TI10465a...

Страница 17: ...h hydraulic oil consumption curve dashes Follow right to scale to read hydraulic oil consumption See Models on page 3 for your pump part number 0 0 1 3 8 2 7 6 3 11 4 4 15 1 5 18 9 6 22 7 0 1 3 8 2 4...

Страница 18: ...0 2 4 6 8 10 12 14 0 2 7 6 4 15 1 6 22 7 8 30 3 10 37 9 12 45 4 14 53 0 50 3 4 0 34 100 6 9 0 69 150 10 3 1 03 200 13 8 1 38 250 17 2 1 72 300 20 7 2 07 A B C Viscount II Motor 3000cc Lower FLUID PRES...

Страница 19: ...3 bar Maximum recommended cycle rate for continuous duty 12 cycles per minute Hydraulic oil consumption See Performance Charts page 17 Dimensions See Dimensions page 15 Weight See Dimensions page 15 M...

Страница 20: ...material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANT...

Отзывы: