Performance Charts
3A6939B
17
Performance Charts
To find Fluid Outlet Pressure (psi/MPa/bar) at a spe-
cific fluid flow (lpm/gpm) and operating hydraulic pres-
sure (psi/MPa/bar):
1.
Locate desired flow along bottom of chart.
2.
Follow vertical line up to intersection with selected
fluid outlet pressure curve (black). Follow left to
scale to read fluid outlet pressure.
To find Motor Hydraulic Oil Consumption (l/min. or
gpm) at a specific fluid flow (l/min. or gpm):
1.
Locate desired flow along bottom of chart.
2.
Read vertical line up to intersection with hydraulic oil
consumption curve (dashes). Follow right to scale to
read hydraulic oil consumption.
See Models on page 3 for your pump part number.
0
0
1
(3.8)
2
(7.6)
3
(11.4)
4
(15.1)
5
(18.9)
6
(22.7)
0
1
(3.8)
2
4
6
8
10
12
14
16
0
2
(7.6)
3
(11.4)
4
(15.1)
5
(18.9)
6
(22.7)
7
(26.5)
8
(30.3)
9
(34.1)
10
(37.9)
50
(3.4,0.34)
100
(6.9,0.69)
150
(10.3,1.03)
200
(13.8,1.38)
250
(17.2,1.72)
300
(20.7,2.07)
350
(24.1,2.41)
400
(27.6,2.76)
450
(31.0,3.10)
500
(34.8,3.48)
A
B
C
Viscount II Motor, 2500cc Lower
FLUID
PRESSURE, psi (M
Pa, bar)
FLUID FLOW, gpm (lpm)
CYCLES PER MIN.
HYDR
AULIC OIL CONSUMPTIO
N
Key:
A
10.3 MPa, 103 bar (1500 psi)
hydraulic pressure
B
7.2 MPa, 72.4 bar (1050 psi)
hydraulic pressure
C
4.1 MPa, 41 bar (600 psi)
hydraulic pressure
Fluid outlet pressure